USING YOUR ELECTRONIC CONTROL
Control lock
The control panel can be locked to avoid unintentional
changes. To lock the control, press and hold the "Lock" key-
pad until the display reads "Loc" then immediately release
your finger from the keypad. The lock icon will flash 3-times
and then continuously illuminate. When the control panel is
locked, only the Lock keypad, System Status OK indicator
, and the Alarm indicator are active. To un-lock the control
panel, repeat this instruction until the display reads "nLc"
then immediately release your finger from the keypad.
NOTE
If the control lock is active (illuminated lock icon) the
control will have to be unlocked before using the
keypad to reset an alarm condition. See page 12
(Control Lock) for instructions for unlocking the control.
Temperature Sensor Error Codes
The temperature sensors are monitored continuously. Any
OPEN or SHORTED circuit condition will initiate an
ERROR CODE as listed below:
Sensor
Displayed Code
Refrigerator
Temperature
Sensor
Freezer
Temperature
Sensor
Defrost Sensor
12
CARE AND USE/INSTALLATION
Alarms
The control will alert you to conditions that could adversely
affect the performance of the appliance.
Temperature Sensor Error Codes
Error Description
Failed temperature sensor in the
refrigerator compartment. Can lead to
unwanted storage temperatures and/or
spoiled perishable goods.
Failed temperature sensor in the
freezer compartment. Can lead to
unwanted storage temperatures and/or
spoiled perishable goods.
Failed defrost temperature sensor.
Causes unit to not defrost properly and
can create large frost build-up. Can lead
to water damage to the unit and sur-
rounding floor.
Door Ajar
Door ajar -
If the door is open, or not closed prop-
erly, for more than 5-minutes the System Status OK
indicator will turn-off, the "Door Ajar" indicator will flash,
and a tone will sound every 60 seconds. Additionally,
an "ALARM RESET" indicator will be displayed below
the "On/Off" keypad.
NOTE
The audible alarm can be muted, for each occurrence,
by pressing the lock keypad.
This alarm condition can be reset by closing the door or
momentarily pressing the "On/Off" keypad, (i.e.-if you
are cleaning the storage compartment, etc.). The alarm
will recur in 5-minutes if the alarm condition persists.
Call service to have the
temperature sensor replaced and
remove all perishable goods from com-
partment to prevent spoilage.
Call service to have the
temperature sensor replaced and
remove all perishable goods from com-
partment to prevent spoilage.
Unplug the power cord
immediately and call service to have
the defrost sensor replaced.
ALARM RESET
Action to Take

Publicidad