Error codes:
The ice machine is monitored continuously. Any OPEN or
SHORTED circuit condition with a temperature sensor or
miscommunications between the control and user interface
will initiate an ERROR CODE as listed below:
Error
"OFF" will flash continuously in 1
Bin Sensor error
second intervals in the display. No
audible alarm will sound.
"ICE" will flash continuously in
System Sensor error
the display. No audible alarm will
Continual flashing of all indicators
Communication error
Options menu:
Normal and ECO mode:
Your ice machine comes with an optional "ECO" mode.
This new feature allows you to tailor ice production to a
conservative rate, saving approximately 25% energy and
30% water from routine operation. While in this
mode ice production will slow and the appliance
will use less water and electricity. "ECO" mode
should only be initiated after there is a full bin of ice.
To enter "ECO" mode do the following:
Press the "MENU" icon twice and the green
"ECO" will flash.
Press and hold the "ON/OFF" icon until the green
"ECO" stops flashing and remains illuminated.
To return to the standard operating rate press
the "MENU" icon twice, the ECO will turn off
and the "ICE" will be flashing. Press and hold
the "ON/OFF" icon until the "ICE" stops flashing and
remains illuminated.
USING YOUR ELECTRONIC CONTROL
Displayed Code
Failed temperature sensor. Machine operation will imme-
Failed condenser temperature sensor. Machine opera-
tion will continue but ice production cycle will not adapt to
sound.
varying ambient conditions, so ice quality may vary.
Loss of communication between the main board and the
on the display.
ECO
Error Codes
Error Description
diately enter an OFF state.
user interface.
ICE
16
Action to Take
Call service to have the
temperature sensor replaced.
Call service to have the
temperature sensor replaced.
Call service to have a
diagnostic check.

Publicidad