Attention! Before memorising the transmitters for the first time remember to cancel
the entire memory content.
1. Cancelling the entire memory content
1a
Remove jumper "J2" from the interface
1b
Press button "P1" 4 times in sequence
on the interface and the fourth time hold it down
for 6 seconds.
1c
The green LED "L1" and the red LED "L2"
will flash and remain lit during cancelling
1d
The red LED "L2" switches off and the
green LED "L1" will flash for a few seconds then
it too will switch off
At this point all codes have been cancelled!
2. Memorising the programming function access code
for remote memorisation from the keyboard
2a
Insert jumper "J2" on the interface
2b
Press button "P1" for at least six seconds
2c
Red LED "L2" on the interface will flash
PROGRAMMING PROCEDURE