Descargar Imprimir esta página

DHC EBT900 Manual Del Usuario página 10

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
BAD CELL & REPLACE
*The battery has at least one cell short circuit. It
should be replaced immediately.
LOAD ERROR
*The tested battery is bigger than
2000CCA/SAE or 200AH. Or the clamps are
not connected properly. Please fully charge the
battery and retest after excluding both previous
reasons. If reading is the same, the battery
should be replaced immediately.
14. SOC & SOH Display: Press directional keys to see SOC & SOH:
GOOD & PASS
SOC:
■■■■■■■■■□ 90%
15. Press the ◄ ► key to select result printing:
YES or NO. Press «ENTER» to confirm your
choice.
*24V System Test Printing: The printer will
not function for 24 Volt batteries system
test printing. The 24V system test result
will be recorded till you hook up to a 12V
battery and the right screen shows up. Please select "YES" and press
enter key to print the result and then disconnect the clamps. The screen
will appear again after you reconnect the clamps. Please select "NO" and
press the enter key to go back to the main menu.
16. Press «ENTER» return to MAIN MENU or remove the test clamps from the
battery posts after completion of testing batteries to end test.
xx.xx V
VOL:
CCA:
IR:
SOH:
PRINT 24V SYSTEM
RESULT?
10
BAD CELL &
REPLACE
xx.xx V
xxxx CCA/SAE
xx.xx mΩ
LOAD ERROR
GOOD & PASS
xxxx CCA/SAE
■■■■■■■■■□ 90%
PRINT RESULT?
YES/NO
YES
NO

Publicidad

loading