Descargar Imprimir esta página

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Enlaces rápidos

CARDIN ELETTRONICA spa
Via del lavoro, 73 – Z.I. Cimavilla
3 1 0 1 3 C o d o g n è ( T V ) I t a l y
Tel:
Fax:
email (Italian): Sales.office.it@cardin.it
email (Europe):
Http:
AUTOMAZIONE PER CANCELLI A BATTENTE
AUTOMATISME POUR PORTAILS BATTANTS
AUTOMATISIERUNG FÜR FLÜGELTORE
AUTOMATIZACIÓN PARA CANCILLAS BATIENTES
ITALIANO
ATTENZIONE! Prima di iniziare l'installazione leggere le
istruzioni attentamente!
Impianto tipo
Schema di montaggio
Schema elettrico (impianto tipo)
Avvertenze importanti
Istruzione per l'installazione
Sblocco manuale
Collegamento elettrico
Procedura di programmazione
Menu di visualizzazione
Comando via radio
Modalità di funzionamento
Funzionamento a batteria
Indicazioni del display
Caratteristiche tecniche
ENGLISH
ATTENTION! Before installing this device read the
following instructions carefully!
Installation example
Assembly
Wiring diagram (installation example)
Important remarks
Installation instructions
Manual release mechanism
Electrical connection
Programming procedure
Display mode
Remote control
Function modes
Battery powered operation
Indications on the display
Technical specifications
+39/0438.404011
+39/0438.401831
Sales.office@cardin.it
www.cardin.it
AUTOMATION FOR HINGED GATES
Pagina
Pagine
Pagina
Pagina
Pagine
Pagina
Pagine
Pagina
Pagina
Pagina
Pagine
Pagina
Pagina
Pagina
Page
Pages
Page
Page
Pages
Page
Pages
Page
Page
Page
Pages
Page
Page
Page
BL
Instruction manual
ZVL476.02
Questo prodotto è stato testato e collaudato nei laboratori della casa costruttrice, la quale ne ha verificato la
perfetta corrispondenza delle caratteristiche con quelle richieste dalla normativa vigente. This product has been
tried and tested in the manufacturer's laboratory who have verified that the product conforms in every aspect to
24Vdc
the safety standards in force. Ce produit a été testé et essayé dans les laboratoires du fabriquant. Pour l'installer
suivre attentivement les instructions fournies. Dieses Produkt wurde in den Werkstätten der Herstellerfirma
Motors
auf die perfekte Übereinstimmung ihrer Eigenschaften mit den von den geltenden Normen vorgeschriebenen
getestet und geprüft. Este producto ha sido probado y ensayado en los laboratorios del fabricante, que ha
comprobado la perfecta correspondencia de sus características con las contempladas por la normativa vigente.
24Vdc Motors 200/BL1924ASW
ATTENTION! Avant de commencer la pose, lire
attentivement les instructions!
Exemple d'installation
Schéma de montage
Schéma électrique (exemple d'installation)
Consignes importants
Instructions pour l'installation
Déverrouillage manuel
Branchement électrique
Procédé de programmation
Menu de visualisation
Commande via radio
Modes de fonctionnement
Fonctionnement à batterie
Indications de l'afficheur
Caractéristiques techniques
ACHTUNG! Bevor mit der Installation begonnen wird, sollte
die Anleitung aufmerksam gelesen werden!
2
Anlagenart
3-7
Montagegearbeiten
8
Elektrischer Schaltplan (Anlagenart)
9
Wichtige Hinweise
9-10
Installationsanleitung
10
Manuelle Entriegelung
10-11
Elektrischer Anschluss
12
Programmierverfahren
13
Anzeigemenü
14
Funkbefehl
14-15
Betriebsmodus
15
Batteriebetrieb
16
Displayanzeigen
52
Technische Eigenschaften
¡ATENCIÓN! Antes de iniciar la instalación del sistema,
leer atentamente las instrucciones.
2
Instalación estándar
3-7
Esquema de montaje
8
Esquema eléctrico (instalación estándar )
17
Advertencias importantes
17-18
Instrucciones para la instalación
18
Desbloqueo manual
18-19
Conexionado eléctrico
20
Procedimiento de programación
21
Menú de visualización
22
Mando vía radio
22-23
Modalidad de funcionamiento
23
Funcionamiento por batería
24
Indicaciones en el display
52
Datos técnicas
1
Series
Model
BL
1924ASW
FRANÇAIS
Page
Pages
Page
Page
Pages
Page
Pages
Page
Page
Page
Pages
Page
Page
Page
DEUTSCH
Seite
Seiten
Seite
Seite
Seiten
Seite
Seiten
Seite
Seite
Seite
Seiten
Seite
Seite
Seite
ESPAÑOL
Página
Páginas
Página
Página
Páginas
Página
Páginas
Página
Página
Página
Páginas
Página
Página
Página
Date
07-03-2005
2
3-7
8
25
25-26
26
26-27
28
29
30
30-31
31
32
52
2
3-7
8
33
33-34
34
34-35
36
37
38
38-39
39
40
52
2
3-7
8
41
41-42
42
42-43
44
45
46
46-47
47
48
52

Publicidad

loading

Resumen de contenidos para CARDIN ELETTRONIC BL1924ASW

  • Página 1 AUTOMAZIONE PER CANCELLI A BATTENTE AUTOMATION FOR HINGED GATES AUTOMATISME POUR PORTAILS BATTANTS AUTOMATISIERUNG FÜR FLÜGELTORE AUTOMATIZACIÓN PARA CANCILLAS BATIENTES 24Vdc Motors 200/BL1924ASW FRANÇAIS ATTENTION! Avant de commencer la pose, lire attentivement les instructions! Exemple d’installation Page Schéma de montage Pages Schéma électrique (exemple d’installation)
  • Página 2 ESEMPIO D'INSTALLAZIONE - INSTALLATION EXAMPLE - EXEMPLE D'INSTALLATION - ANLAGENART - INSTALACIÓN ESTÁNDAR LEGENDA Motoriduttore (SX) Motoriduttore (DX) - 5 0 Fotocellula interna Fotocellula esterna Lampeggiatore Selettore a chiave Elettroserratura Antenna esterna (Cavo coassiale RG58 Impedenza 50Ω) Interruttore onnipolare con apertura contatti min. 3 mm 10 Cavo alimentazione principale 230 Vac 11 Canalatura per cavo Cardin CABPC10 12 Canalatura per collegamenti a bassa tensione...
  • Página 3 All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by Ø25 Description : ISTRUZIONE PER IL MONTAGGIO Drawing number : DM0746 MONTAGGIO BL1924ASW Product Code : BL1924ASW Date : 16-05-2005 Draft : P.J.Heath...
  • Página 4 LIMITI D’IMPIEGO - LIMITS OF USE - CONTRAINTES D'UTILISATION - ANWENDUNGSGRENZEN - LIMITES DE EMPLEO ESEMPIO D’INSTALLAZIONE-INSTALLATION EXAMPLE-EXEMPLE D'INSTALLATION-ANLAGENART-EJEMPLO DE INSTALACIÓN Description : DI0156 BL1924 BL1924 POSIZIONAMENTO BASE MOTORE E STAFFA ANTERIORE - POSITIONING THE MOTOR SUPPORT BASE AND REAR BRACKET 04-03-2000 Date : MISE EN PLACE DE L’EMBASE DU MOTEUR ET DE LA PATTE ANTÉRIEURE...
  • Página 5 FISSAGGIO BASE MOTORE AL PILASTRO - FASTENING THE MOTOR TO THE COLUMN - FIXATION DE L’EMBASE DU MOTEUR AU PILIER BEFESTIGUNG DER MOTORGRUNDPLATTE AM PFEILER - FIJACIÓN DE LA BASE DEL MOTOR EN EL PILAR All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law 1 8 0 FISSAGGIO BRACCIO ALL’ALBERO MOTORE - FASTENING THE OPERATOR ARM TO THE MOTOR FIXATION DU BRAS À...
  • Página 6 ISTRUZIONE PER IL MONTAGGIO Drawing number : DM0745 Rotture apertura albero 2 BL1924 Product Code : BL1924ASW Date : 17-05-2005 Draft : P.J.Heath CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831...
  • Página 7 Drawing number : DM0748 All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law Applicazione Carter Product Code : BL1924ASW Draft : P.J.Heath Date : 16-05-2005 CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831 ELETTROSERRATURA (OPZIONALE) - ELECTRIC LOCKING DEVICE (OPTIONAL) - SERRURE ÉLECTRIQUE (EN OPTION)
  • Página 8 Gelb Amarillo Rojo Schwarz Negro ENCODER 1 ENCODER 2 LC/CH2 FTC-TX 24V 12V 0 BL1924ASW M1 BL1924ASW M2 FTC-RX ENCODER 1 ENCODER 2 Bl Gr Gy Yw Bl Gr Gy Yw Collegamenti scheda base Description : Drawing number : DI0518...
  • Página 9 AVVERTENZE IMPORTANTI AVVERTENZE IMPORTANTI AVVERTENZE IMPORTANTI LEGGERE ATTENTAMENTE LE SEGUENTI AVVERTENZE PRIMA DI PROCEDERE ALL’INSTALLAZIONE. PRESTARE PARTICOLARE ATTENZIONE A TUTTE LE SEGNALAZIONI DISPOSTE NEL TESTO. IL MAN- CATO RISPETTO DI QUESTE POTREBBE COMPROMETTERE IL BUON FUNZIONAMENTO DEL SISTEMA E CREARE SITUAZIONI DI PERICOLO GRAVE PER L'OPERATORE E GLI UTILIZZATORI DEL SISTEMA STESSO. •...
  • Página 10 • Procedere quindi con il montaggio del braccio articolato completo di staffa di attacco al cancello (fig. 2): • Dopo aver installato il dispositivo, e prima di dare tensione alla - inserire le boccole in plastica "11" nei fori del braccio curvo "7", collegare centralina, verificare che il movimento del cancello eseguito in il braccio curvo "7"...
  • Página 11 Collegamenti morsettiera - in posizione 1 si seleziona la costa con contatto NC; - in posizione 2 si seleziona la costa di sicurezza con contatto 8.2 kΩ; CMN comune per tutti gli ingressi/uscite Se si ponticella l'ingresso CSP, posizionare il jumper "J6" in posizione 1 (NC). ELS uscita per elettroserratura (pilotata in continua) 12 Vdc –...
  • Página 12 PROCEDURA DI PROGRAMMAZIONE (Impostazioni del programmatore e del sensore di corrente) • È obbligatoria la presenza delle battute di apertura e chiusura per entrambe le ante. • Accertarsi che le sicurezze siano a riposo e che la scheda sia alimentata da rete: in caso contrario non si entra in programmazione. •...
  • Página 13 MENU DI VISUALIZZAZIONE Agendo sul tasto PROG si accede in sequenza alle seguenti funzioni: - regolazione del sensore di corrente; - memorizzazione dello stato dei dip-switch; - selezione del tipo di motore; - visualizzazione dello stato dei comandi e delle sicurezze; - impostazione funzione richiusura con ostacolo.
  • Página 14 Memorizzazione di ulteriori canali via radio COMANDO VIA RADIO (figura 14 - pagina 8) • La memorizzazione può essere anche attivata via radio (senza aprire la scatola È possibile azionare a distanza l'automazione tramite radiocomando; per dove è alloggiata la centralina) se il jumper "J3" (fig. 14) è inserito. configurare le due funzioni sui canali A-B-C-D si utilizzano i jumper di selezione "J4": 1.
  • Página 15 4) Manovra di emergenza Ne consegue che l’esecuzione del comando, qualora consentita (sicu- Nel caso in cui il programmatore elettronico non dovesse più rispondere ai comandi rezze a riposo) verrà ritardata per il tempo necessario alla ripresa del per un malfunzionamento, agire sugli ingressi EMRG1 o EMRG2 per muovere corretto funzionamento dei dispositivi stessi (circa 1 secondo).
  • Página 16 Segnalazioni di funzionamento INDICAZIONI DEL DISPLAY (D1 - pagina 8) Visualizzazioni all’accensione Programmazione del tempo di pausa Visualizzato per due secondi: "CC242C" = modello della centralina Programmazione automatica in corso segnala la memorizzazione della configurazione dei dip-switch e la Nella programmazione indica che il sistema si è versione del firmware.
  • Página 17 IMPORTANT REMARKS IMPORTANT REMARKS IMPORTANT REMARKS READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLA- TION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORK- ING ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM. •...
  • Página 18 To install the motor to the left first remove the plastic disk "H" (fig.10) which • After having installed the device, and before powering up the blocks the hole required for the motor drive shaft, using a pair of pliers and programmer, release the door (manual release mechanism) and then cover the other hole using the supplied mobile disk "L".
  • Página 19 Terminal board connections Note The total of the 2 external device outputs must not exceed 10 W. Note Jumper "J6" identifies the type of safety edge connected to binding post 24: CMN common for all inputs and outputs. - in position 1 the safety edge with NC contact is selected; ELS electric lock output (fed continuously) 12 Vdc - 15 W.
  • Página 20 PROGRAMMING PROCEDURE (Setting the programmer and the current sensor) • The installation of both anti-derailment buffers is absolutely obligatory before starting programming. • Make sure the safety devices are at rest and the ECU is receiving mains power otherwise you will not be able to enter programming. •...
  • Página 21 DISPLAY MENU Using the PROG button you can access the following functions in sequence: - selecting the type of motor; - memorising the status of the dip-switches; - reclosure after encountering an obstacle; - display the status of the command and safety devices; - motor power setting - display the number of manoeuvres;...
  • Página 22 1. Make sure that the jumper "J3" has been inserted (fig. 14). REMOTE CONTROL (fig. 14 - page 8) 2. Using a transmitter, in which at least one channel button "A, B, C or D" has The system can be remotely activated using radio control devices; to set the already been memorised in the receiver, press the button in the transmitter two functions to channels A-B-C-D use the selection jumper “J4”: as shown in figure.
  • Página 23 4) Emergency manoeuvre If after this period a security device is found to be in alarm the command If the electronic programmer no longer responds to commands due to a will not be carried out, power to the external devices will be cut off and malfunction you may use the EMRG1 or EMRG2 inputs to move gate leaf the programmer will return to stand-by.
  • Página 24 INDICATIONS ON THE DISPLAY (D1 - page 8) Operational indications Start up display Pause time programming Shown for 2 seconds: "CC242C" = ECU model; Automatic programming under way Indicates the dip-switch setting memorisation stage and firmware version During programming this means that the system is set to single gate leaf operation Alarm indications Serial line (CSER) active...
  • Página 25 CONSIGNES IMPORTANTES! CONSIGNES IMPORTANTES! CONSIGNES IMPORTANTES! LIRE ATTENTIVEMENT LES CONSIGNES SUIVANTES AVANT DE PROCÉDER À LA POSE. PRÊTER GRANDE ATTENTION À TOUTES LES SIGNALISATIONS QUI SE TROUVENT DANS LE TEXTE. LE NON RES- PECT DE CES CONSIGNES POURRAIT COMPROMETTRE LE BON FONCTIONNEMENT DU SYSTÈME. •...
  • Página 26 Pour un montage à gauche, détacher, au moyen d’une pince, la partie en • Après avoir monté le dispositif, et avant de mettre sous tension plastique "H" (fig. 10) qui obture le trou de passage de l’arbre du moteur et la centrale, contrôler en manœuvrant manuellement le portail (avec boucher au moyen de l’obturateur "L", fourni en dotation, le trou inutilisé.
  • Página 27 Branchements du bornier Nota Le cavalier "J6" permet de sélectionner le type de bord de sécurité branché à la borne 24: CMN commun pour toutes les entrées/sorties - en position 1, sélection du bord de sécurité avec contact N.F., ELS sortie pour serrure électrique (pilotée en continu) 12 Vdc – 15 W - en position 2, sélection du bord de sécurité...
  • Página 28 PROCÉDÉ DE PROGRAMMATION (configurations du programmateur et du senseur de courant) • Il est obligatoire d’installer les fins de course en ouverture et fermeture pour les deux vantaux. • Contrôler que les dispositifs de sécurité soient en veille et que la carte soit alimentée par le réseau d’alimentation; en cas contraire, il est impossible d’entrer en programmation.
  • Página 29 MENU DE VISUALISATIONS La touche PROG permet d’accéder en séquence aux fonctions suivantes: - programmation du niveau du senseur de courant; - mémorisation du réglage des dip-switches; - sélection du type de moteur; - visualisation de l’état des commandes et des dispositifs de sécurité; - programmation du fonction de refermeture avec obstacle interposé.
  • Página 30 Mémorisation par radio d'autres canaux COMMANDE PAR RADIO (fig. 14 - page 8) • La mémorisation peut être activée également par radio (sans devoir ouvrir le Il est possible d’actionner à distance l’automatisme par le biais d’une télécom- boîtier contenant la centrale), si le cavalier "J3" (fig. 14) a été inséré. mande radio;...
  • Página 31 4) manœuvre d’urgence Il en résulte un retard d’exécution de l’ordre (si sécurités à l’état de veille) En cas de défaillance du programmateur électronique qui ne répond plus aux correspondant au temps nécessaire à la reprise du fonctionnement correct commandes, intervenir sur l’entrée EMRG1 ou EMRG2 pour manœuvrer le vantail de ces dispositifs (environ 1 seconde).
  • Página 32 Signalisations de fonctionnement INDICATIONS SUR L’AFFICHEUR (D1, page 8) Visualisations à l’allumage Programmation du temps de pause visualisé pendant deux secondes: “CC242C” = modèle de la centrale Programmation automatique en cours signale la mémorisation de la configuration des dip-switches Indique en phase de programmation que le système et la version du firmware.
  • Página 33 WICHTIGE HINWEISE WICHTIGE HINWEISE WICHTIGE HINWEISE VOR DER INSTALLATION SOLLTEN DIE NACHSTEHENDEN HINWEISE AUFMERKSAM GELESEN WERDEN. BESONDERE AUFMERKSAMKEIT SOLLTE ALLEN IM TEXT BEFINDLICHEN HINWEISEN GESCHENKT WERDEN. DEREN NICHTBEACHTUNG KÖNNTE DEN ORDENTLICHEN BETRIEB DES SYSTEMS BEEINTRÄCHTIGEN. • Das vorliegende Handbuch wendet sich an Personen, die zur Installation von BENUTZERHINWEISE "Elektrogeräten"...
  • Página 34 Der Getriebemotor wird werksmäßig für die Montage auf der rechten Torseite • Nachdem die Vorrichtung installiert wurde und bevor die Steu- (von innen gesehen) geliefert. Für die Montage auf der linken Seite muss das erung mit Strom versorgt wird, muss überprüft werden, dass der Plastikteil "H"...
  • Página 35 Anschlussklemmleisten-Anschlüsse Anmerkung Der Jumper "J6" wählt den Typ der an Klemme 24 angeschlossenen CMN Neutralleitung für alle Eingänge/Ausgänge Sicherheitsleiste aus: - In Position 1 wird die Leiste mit NC-Kontakt ausgewählt; ELS Ausgang für Elektroschloss (ununterbrochen gesteuert) 12 Vdc – 15 W - In Position 2 wird die Sicherheitsleiste mit Kontakt 8.2 kΩ...
  • Página 36 PROGRAMMIERVERFAHREN (Einstellungen der Steuerung und des Strommess-Sensors) • Das Vorhandensein der Öffnungs- und Schließungsanschläge ist für beide Torflügel obligatorisch. • Sich vergewissern, dass die Sicherheitsvorrichtungen sich in Ruhestellung befinden und dass die elektronische Leiterplatte mit Netzstrom versorgt wird; andernfalls ist der Eintritt in die Programmierung nicht möglich. •...
  • Página 37 MENU DER ANZEIGE - Einstellung der Stromsensorstufe; Durch Betätigung der Taste PROG erfolgt der Zugriff zu den folgenden Funktionen: - Motorentypwahl; - Speicherung des Zustands der Dip-Schalter; - Einstellung der Schließfunktion bei einem Hindernis. - Anzeige des Zustands der Steuerungen und der Sicherheiten; - Einstellung der Motorleistung - Anzeige der Anzahl der Manöver;...
  • Página 38 Speicherung weiterer Kanäle über Funk FERNBEDIENUNG (Abb. 14 - Seite 8) • Die Speicherung kann auch über Funk (ohne den Behälter zu öffnen, in dem die Steuereinheit untergebracht ist) aktiviert werden, falls der Jumper "J3" Die Automatisierung kann mittels einer Funkfernsteuerung ferngesteuert werden; (Seite 8) eingesetzt worden ist.
  • Página 39 4) Notfall-Betätigung • Bei blockiertem Tor werden zum Sparen des Batteriestromes die kontrollierten externen Stromverbraucher (CTRL 30 Vdc) nicht mit Strom versorgt. Wenn ein Wenn die elektronische Steuerung wegen eines Defektes nicht mehr auf die Befehl (über Kabelleitung oder Funk) gegeben wird, versorgt die Steuerung Befehlseingabe anspricht, sind die Eingänge EMRG1 oder EMRG2 zur manuellen zuerst die Stromverbraucher und bewertet den Zustand der Sicherheitsvor- Betätigung des Torflügels 1 zu verwenden.
  • Página 40 Betriebsfunktionsmeldungen DISPLAY-ANZEIGEN (D1 - Seite 8) Anzeigen beim Anschalten Programmierung der Pausenzeit Anzeige für zwei Sekunden: "CC242C" = Steuereinheitsmodell Automatische Programmierung im Gange Signalisiert die Speicherung der Konfiguration der Dip-Schalters Zeigt bei der Programmierung an, dass das System sich und der Firmwareversion. auf die Betriebsweise mit einem einzelnen Torflügel eingestellt hat Alarmsignale...
  • Página 41 ADVERTENCIAS IMPORTANTES ADVERTENCIAS IMPORTANTES ADVERTENCIAS IMPORTANTES LÉANSE ATENTAMENTE LAS SIGUIENTES ADVERTENCIAS ANTES DE PROCEDER CON LA INSTALACIÓN DEL SISTEMA. PRESTAR PARTICULAR ATENCIÓN A TODAS LAS SEÑALIZACIONES QUE HAN SIDO INDI- CADAS EN EL TEXTO , YA QUE EL INCUMPLIMIENTO DE LAS MISMAS PODRÍA PERJUDICAR EL BUEN FUNCIONAMIENTO DEL SISTEMA.
  • Página 42 El motorreductor se suministra de fábrica para el montaje a la Dcha. de la • Tras haber instalado el dispositivo y –antes de proporcionar tensión a cancilla (vista interior), para el montaje a la Izda. se debe quitar la pieza de la centralita–...
  • Página 43 Conexionado placa de bornes Nota El puente "J6" selecciona el tipo de banda sensible conectada con el borne 24: - en posición 1 se selecciona la banda sensible con contacto NC; CMN Común para todas las entradas/salidas - en posición 2 se selecciona la banda sensible de seguridad con contacto 8.2 kΩ; ELS salida para cerradura eléctrica (controlada en continuo) 12 Vdc–15W Si se puentea la entrada CSP, situar el puente "J6"...
  • Página 44 PROCEDIMIENTO DE PROGRAMACIÓN (Fijación entradas programador y sensor de corriente) • Es obligatoria la presencia de los topes de apertura y cierre para las dos hojas. • Controlar que los dispositivos de seguridad se encuentren en la posición de reposo y que la tarjeta esté alimentada por la red eléctrica; en caso contrario, no se entrará...
  • Página 45 MENÚ DE VISUALIZACIÓN Actuando sobre la tecla PROG, se accede -en secuencia- a las siguientes funciones: - configuración del nivel del sensor de corriente; - memorización del estado de los dip-switches; - selección del tipo de motor; - visualización del estado de los dispositivos de mando y seguridad; - configuración función de cierre con obstáculo;...
  • Página 46 Memorización de otros canales vía radio MANDO VÍA RADIO (fig. 14 - pág. 8) • La memorización se puede activar también vía radio (sin abrir el contenedor Es posible accionar a distancia la automatización por medio del radiomando; donde está alojada la centralita) si el jumper "J3" está inserido (fig. 14). para configurar las dos funciones en los canales A-B-C-D, se utilizan el puente 1.
  • Página 47 4) Maniobra de emergencia Resulta que la ejecución del mando, si está permitida (dispositivos de seguridad Si el programador electrónico no reaccionara a los controles por un mal fun- en reposo), será diferido por el tiempo necesario para el correcto funcionamiento cionamiento, actuar sobre las entradas EMRG1 o EMRG2 para mover la hoja de los dispositivos mismos (aproximadamente 1 segundo).
  • Página 48 Señalizaciones de funcionamiento INDICACIONES EN EL DISPLAY (D1 - página 8) Visualizaciones tras el encendido Programación del tiempo de pausa Visualizado por dos segundos: "CC242C" = modelo de la centralita Programación automática en curso Señaliza la memorización de la configuración de los dip-switches y la versión del firmware.
  • Página 49 NOTES...
  • Página 50 NOTES...
  • Página 51 E non funzIonAntE In moDo InDIpEnDEntE: Motoriduttore serie BL Nome dell'apparato Automazione a 24 Vdc per cancelli a battente con centralina esterna Tipo di apparato BL1924ASW - centrale di comando CC242ESSB Modello Marchio Cardin Elettronica Anno di prima fabbricazione 2005 è...
  • Página 52 CARATTERISTICHE TECNICHE TECHNICAL SPECIFICATIONS Specifiche tecniche dell'attuatore Operator arm specifications Alimentazione Power supply Assorbimento Nominal current yield Potenza assorbita Maximum power yield Ciclo di lavoro Duty cycle Velocità riduttore giri/min Shaft revolutions revs/min Coppia Torque Grado di protezione Protection grade Specifiche tecniche della centralina Electronic programmer specifications: Alimentazione...