AC24NE
Photocell Logic
Photocell OPEN/CLOSE (Standard set up)
Position of Gate
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Safety Edge
Position of Gate
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
Open Only Device (Vehicle detector)
Position of Gate
Type of Safety Device
FULLY CLOSED
FULLY OPENED
STOP DURING MOVING
CLOSING
OPENING
When safety devices are activated
PH1
Photocell-CLOSE
No effect
Reload automatic closing time
Reload automatic closing time
Open
No effect
When safety devices are activated
PH1
Photocell-CLOSE
No effect
Reload automatic closing time
Reload automatic closing time
Open
No effect
When safety devices are activated
PH1
Photocell-CLOSE
No effect
Reload automatic closing time
Reload automatic closing time
Open
No effect
Opening your life
PH2
Photocell-OPEN
Open not allowed
No effect
Open not allowed
No effect
Close
PH2
Safety Edge
Open not allowed
OPEN/CLOSE not allowed
Reverse to open for 2 seconds
Reverse to close for 2 seconds
PH2
Opening Device
Open
Open
Open
No effect
1 23