Descargar Imprimir esta página

Presenza QR065 Manual Del Usuario página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

Pre-Installation (continued)
PLANNING INSTALLATION
Number of people required: 2 or more
Carefully check the range hood for damage and for missing parts
prior to installation . If there is any damage or if you are missing
parts, do not proceed with the installation . Report damage and
missing parts immediately . Do not dispose of packaging before you
are satisfied with your new range hood.
1 . Before installation, measure all distances to ensure the proper
position of the range hood (A) .
- The distance (1) from the cooking surface to the range hood
must be at least 18 in. (458 mm). For the best performance,
do not install the range hood more than 28 in. (710 mm)
above the cooking surface .
- Dimension (3) should be at least 30" (762 mm) . The range
hood should be approximately the same size as the cook
top .
2 . If the bottom of the cabinet (6) above the location where the range
hood is to be installed is recessed, attach appropriately sized wood
filler strips (7) on each side using wood screws.
3 . Screws are provided to secure the range hood to most types of
cabinets, but consult a qualified installer to verify that the supplied
screws are suitable for your cabinets .
4 . Put a thick, protective covering over your counter, cooktop, or
range to protect it from damage and dirt during installation .
Remove any hazardous objects around the area .
VENTING OPTIONS
A . Determine if your existing venting system is top venting (rectangular duct or 7" round duct) or back venting, and ensure that the
openings in the cabinet or wall for the damper and for power access are in appropriate locations and are of appropriate sizes . See Fig . 3
for top venting installations and Fig . 4 for back venting installations .
B . If this is a new installation, choose the venting method that suits your needs . Cut out openings for the damper and for power access in
the cabinet bottom or exterior wall . See Fig . 3 for top venting installations and Fig . 4 for back venting installations .
Rectangular duct
10-1/4"
260
Fig.3
Top Venting
Round duct
2.1"
54 mm
4.37"
111 mm
7
Please contact cs@conglomkb.com or 1-877-333-0098 for further assistance.
WARNING: Always wear safety goggles and gloves
during installation .
4
6
7
ø 7.87"
ø 200 mm
11.2"
285 mm
ø1.26"
1.53"
ø32 mm
39 mm
7
7
A
3
3
Fig. 2
Back Venting
10-1/4"
260
Fig.4
CONGLOMKB .COM
1

Publicidad

loading