Hardwire Instructions
> The electrical connections will be made while the mirror is
resting on the floor. Do not attempt to lift the mirror while
making electrical connections!
> Make sure that the circuit is off at the breaker. Locate the
hardwire box on the back of the mirror. Select one of the
1/2" knockouts on the hardwire box that will be used for
wiring the box and snap it out with a flat-head screwdriver.
> Remove the four screws from the top of the box and slide
the top off. Select an appropriate bushing for the type of
1/2" trade conduit in accordance to the NEC. Install the
bushing in the knockout selected.
> Strip 1/2" to 3/4" of insulation from the power supply
wiring and run through the bushing. Connect the wires
to the terminal block as follows: Red or black wire to "L",
white wire to "N", green or bare wire to "G". See diagram
below:
N
INPUT
G
AC 120 V
50 – 60 Hz
L
Box dimensions: 1-⅜" (deep), 2-¼" (wide), 3-⅝" (long)
> Replace the box top and secure with the four screws.
Connect the conduit to the bushing.
N
G
L
Hardwire Box Module
MAL_Light and Mirror_LM 7822 L/R/19.10.3