3.
Add 3 gallons of hydraulic oil AW32, AW46 & universal hydraulic oil are all acceptable types of
fluid. Automatic transmission fluid should be used when operating in temperatures below
32 degrees (all units are tested and have excess oil in the ram).
4.
Check the hydraulic oil level.
5.
Start engine and use the control lever to extend and retract wedge several times to remove air
from the lines.
6.
With the wedge retracted, check hydraulic oil level again and fill if necessary.
DO NOT remove the hydraulic oil fill cap when the engine is running or hot. Hot oil can escape
causing severe burns. Always allow the log splitter to cool completely before removing the hydraulic
oil cap.
High fluid pressure and temperatures are created in the hydraulic log splitters. Hydraulic fluid will
escape through a pin-size hole opening and can puncture skin and cause severe blood poisoning.
Inspect hydraulic system regularly for possible leaks. Never check for leaks with your hand while
the system is pressurized. Seek medical attention immediately if injured by escaping fluid.
Make sure all fittings are tight and secure before applying pressure. Relieve system pressure before
servicing.
Make sure the hydraulic hoses do not touch any hot surfaces or cutting areas.
Hoses need to be positioned where they are clear from the engine and cutting wedge. To avoid
serious bodily injury always inspect the hoses before operating the log splitter.
Before operating or using the log splitter, review the instructions below and all safety information.
Failure to follow these instructions may result in property damage or injury to the operator or
bystanders.
ALWAYS use the log splitter for its intended use.
ONLY use the log splitter to split wood logs, length wise with the grain.
NEVER modify, alter or change the log splitter in anyway, modifications will void the warranty.
NEVER attach a rope, cable or other device to the control lever on the log splitter.
ONLY operate the log splitter in daylight.
NEVER leave the log splitter unattended while the engine is running.
DO NOT change the splitting position with the engine running. Contact with the muffler can cause
serious burns.
ALWAYS make sure the beam is in the locked position.
DO NOT let the beam drop as it could crush fingers or cause damage to the log splitter.
NEVER operate or let anyone else operate, the log splitter while under the influence of alcohol, drugs,
or medication.
WARNING
Operation Instructions
WARNING
WARNING