Remove personal metal items such as rings, bracelets, necklaces, and watches when
●
working with a lead-acid battery.
A lead-acid battery can produces a short-circuit current high enough to weld a ring or
●
the like to metal, causing severe burns.
FEATURES
Automatic charging
The NOVACAR 10A offers 2 stages automatic charging. Automatic switching from
charging to maintenance mode after battery if fully charged.
LED display
The unit is built-in with LED display for showing charger status:
FULL - GREEN LED – The battery is fully
●
charged and the charger is in maintenance
mode.
CHARGING – AMBER LED – The charger is
●
charging to the battery.
POWER - GREEN LED – The charger is
●
connected to mains power.
REVERSE – RED LED – DC clamps are
●
connected in reverse polarity.
Reverse-polarity protection
This unit offers reverse-polarity protection, the RED "REVERSE" LED will illuminate and
the charging process will not start. If this happens, unplug immediately from mains,
connect the red crocodile clip to positive (+) battery post, and black crocodile clip to
negative (-) post, then plug into the mains power and the charging process will start.
Short-circuit protection
Should you accidentally touch the crocodile clips together whilst the mains power is on,
the unit will not perform charging. Unplug from mains, disconnect and start the process
again being careful not to touch the clips together.
Maintenance mode
When the battery is fully charged, the charger will automatically switch to the
maintenance flow mode charge. The Green "FULL" LED will illuminate. Unplug from
mains, disconnect the battery.
Overload protection
The unit is built-in with an automatic reset circuit breaker. When the charging current
exceeds rated current, the charging process will automatically stop. Unplug from mains,
disconnect the battery and start the process.
9