Technical Details

The electrical characteristics are within
ted values of VmPP, ImPP, Voc and Isc under standardtest conditions (irradiance of 1000 W/m2, AM 1.5 spectrum and a cell
temperature of 25 °C (77 °F)).
Module
Maximum
Type
Power
(P
MPP
CPP 235
235 Wp
CPP 240
240 Wp
CPP 245
245 Wp
CPP 250
250 Wp
CPP 255
255 Wp
CPP 260
260 Wp
+/-3
percent of the indicated value of Pmax and within (9) percent of the indica-
Maximum
Maximum
Power
Power
)
Voltage
Current
(V
)
(I
MPP
29,60 V
8,01 A
29,86 V
8,10 A
30,12 V
8,20 A
30,38 V
8,29 A
30,64 V
8,39 A
30,90 V
8,48 A
Installation manual
Open
Circut
Voltage
)
(V
)
MPP
OC
36,12 V
36,45 V
36,78 V
37,12 V
37,45 V
37,78 V
Conergy
PowerPlus 240-260P
Short
Maximum
Circut
System
Series Fuse
Current
Voltage
(I
)
(V)
SC
8,51 A
1000 V
8,59 A
1000 V
8,68 A
1000 V
8,76 A
1000 V
8,85 A
1000 V
8,93 A
1000 V
Maximum
Rating
(A)
15 A
15 A
15 A
15 A
15 A
15 A

Publicidad