Safety devices
Pressure switch: monitors
depression in the smoke
duct. It is designed to shut
down the pellet feed screw
in the event of an obstructed
flue or significant back-
pressure in the presence
of wind. At the time of the
pressure switch will show
"A A L L
- - D D E E P P - - F A A II L L ".
A A R R
Electrical
safety:
stove is protected against
violent surges of current (ex.
lightnings) by the main fuse
4 A which is located on the
control panel at the rear of
the thermostove. Other fuses
to protect the electronic
boards are to be found on
the boards themselves.
page 36 of 42
Reduction motor: if the
motor stops, the thermostove
continues to function until
the flame goes out for lack of
fuel, and until It has cooled
down to the minimum level.
RESTART
the
Pellets temperature safety:
In the rare event there is a too
high temperature in the tank,
the thermostat for pellets
safety with manual reset
creates an alarm "A A L L A A
R R - - S S II C C - - F F A A II L L " stopping
the pellet boiler stove. You
need to reset the system
working
placed on the back of the
thermostove.
PELLET
on the device
Flue
gas
temperature
sensor: thermocouple that
measures the temperature
of the fumes while keeping
the operation or shuts the
thermostove when the flue
gas temperature drops below
the preset value.
Room
thermostat:
room thermostat detects the
present temperature in the
room. When it detects the set
temperature on the display,
the stove will go into operation
in ECO ie hold function to save
fuel. The room thermostat
should be spread so as not
to be conditioned by the
temperature of the body stove.
the