Reassembly; Trouble Shooting Guide; Motor Not Running - Goulds 3657 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10. Reassembly:

10.1. All parts should be cleaned before assembly.
10.2. Refer to parts list to identify required replacement
items. Specify pump index or catalog number when
ordering parts.
10.3. Reassembly is the reverse of disassembly.
10.4. Observe the following when reassembling the bear-
ing frame:
10.4.1. Replace lip seals if worn or damaged.
10.4.2. Replace ball bearings if loose, rough or
noisy when rotated.
10.4.3. Check shaft for runout at the sleeve area.
Maximum permissible is .002" T.I.R.
10.5. Observe the following when reassembling the
liquid-end:
10.5.1. All mechanical seal components must be in
good condition or leakage may result. Replacement
of complete seal assembly, whenever seal has been
removed, is good standard practice.
It is permissible to use a light lubricant, such as
glycerin, to facilitate assembly. Do not contaminate
the mechanical seal faces with lubricant.
10.5.2. Inspect seal housing o-ring (513) and
replace if damaged. This o-ring may be lubricated
with petroleum jelly to ease assembly.
10.5.3. Inspect impeller o-rings (412A) at the sleeve
and locknut. Replace if damaged.
10.6. Check reassembled unit for binding. Correct as
required.
6

11. Trouble Shooting Guide:

MOTOR NOT RUNNING

(See causes1 through 6)
LITTLE OR NO LIQUID DELIVERED
(See causes 7 through 17)
POWER CONSUMPTION TOO HIGH
(See causes 4, 17, 18, 19, 22)
EXCESSIVE NOISE AND VIBRATION
(See causes 4, 6, 9, 13, 15, 16, 18, 20, 21, 22)
PROBABLE CAUSE:
1. Tripped thermal protector
2. Open circuit breaker
3. Blown fuse
4. Rotating parts binding
5. Motor wired improperly
6. Defective motor
7. Not primed
8. Discharge plugged or valve closed
9. Incorrect rotation
10. Foot valve too small, suction not submerged,
inlet screen plugged
11. Low voltage
12. Phase loss (3-phase only)
13. Air or gasses in liquid
14. System head too high
15. NPSHA too low: Suction lift too high or suction
losses
excessive. Check with vacuum gauge.
16. Impeller worn or plugged
17. Incorrect impeller diameter
18. Head too low causing excessive flow rate
19. Viscosity or specific gravity too high
20. Worn bearings
21. Pump or piping loose
22. Pump and motor misaligned

Publicidad

Tabla de contenido

Solución de problemas

loading

Productos relacionados para Goulds 3657

Este manual también es adecuado para:

3757

Tabla de contenido