Due to the fan's movement, certain fastenings may become loose. Check all fastenings twice per year at a
minimum in order to ensure that they are sufficiently tight. If necessary, they must be retightened.
If the power cord is damaged, it must be replaced by the manufacturer, its after-sales service or similar
qualified personnel in order to avoid any malfunction.
Only suitable for indoors.
Replaceable LED
Replaceable driver
Replaceable receiver
Do not throw away electrical products together with household waste. We ask you to recycle the packaging
at the collection points provided for this purpose. Contact local authorities or your provider for recycling
advice. Thank you for recycling at the collection points provided for this manual.
Note: The important warnings and instructions indicated in this manual are not guaranteed to cover all possible conditions
and situations that may occur. It must be understood that common sense, precaution, and care are factors that cannot be
included in all products. These factors can and must only be provided by the user who maintains and enjoys this fan.
Device technical spectifications
Nominal voltage and frequency
Light wattage
Luminous flux
Light color temperature
Nº of light ON/OFF cycles
Nº of hours of light lifespan
10
Protection category
Protection index
Word temperature
Dimmable/Not dimmable
Maximun ceiling slope on which it can be installed
Light angle
Light Ra
Weight
This product have a light source of energy efficiency class
Speed
Fan power (W)
Fan RPM
Fan airflow (m³/min)
Noise level (dB)
Service value SV ((m³ / min) / W)
Power consumption in standby mode (W)
Service value measurement standard
CIF A28763647
220-240V~AC 50/60Hz
1
2
3
3
5,6
8,2
110
123
191
46,6
60,8
78,3
15
20
25
15,5
10,9
9,5
+34 916774540
Calle Verano, 51 - Polígono Industrial Las Monjas -28850 Torrejón de Ardoz - Madrid (ESPAÑA)
Preparing for installation
Note: The estimated installation time is 120 minutes. This product can only be installed by a certified electrician Carefully
separate the fan's parts, avoiding the use of cutters or blades that could scratch any part of it.
Remote control
3 3
FAN
2 2
OFF
1 1
24W
2000lm
3000/4500/6000K
10000
Syncing the receiver and the remote control for fan operation
30000h
If the receiver and transmitter of this fan are properly synchronized, the fan will work. During synchronization the receiver
Clas I
recognizes the signal from the transmitter, this is called the learning process.
IP20
Make sure the fan is disconnected. This is essential for the synchronization process.
Unless the synchronization process has been successful, the fan will work partially or will not work. By default, all fans have
0
45ºC
↔
been preconfigured at the factory and should be functional once the installation is completed and the fan is turned on.
Not dimmable
If the remote control does not work after installation or during use, synchronization can be performed as indicated below. Note
15º
in any case that there could be other reasons why your fan or remote control does not work:
Make sure all connections are correctly made.
170º
Make sure that the remote control contains batteries.
80
Make sure that all switches (main and isolation) are on.
4,8kg
Instructions for synchronizing the receiver and the remote control
F
The control of this fan does not require synchronization with the recelver, the control is already factory-linked with its receiver;
Universal mode and Unit mode:
- Unit Mode:
This type of synchronization allows you to control two or more nearby fans independently, each with its remote control.
Synchronization:
4
5
6
The control of this fan does not require synchronization with the receiver, the control is already factory-linked with its receiver
12
16,5
24
- Universal Mode:
225
252
285
This type of synchronization allows you to control one or more nearby fans with the same remote control.
96,6 112,5 133,3
Synchronization:
1.-Connect the power (wall switch) of the fan or fans that you want to control, and then just within the following
30
35
40
15 seconds, press the key
8,1
6,8
5,6
2.-A "beep" sound indicates that the connection has been executed and the equipment can function normally.
<0,5
3.-Now, transmitter and receiver of the fan / s will have been synchronized. Turn off the fan / s current using the
EN 62879:2020
switch or automatic and then turn it back on / s, this step is the one that closes the synchronization process.
It is not possible for a controller to forget a fan once it has been linked, if you want a fan to leave
to obey a command, another one must be linked to "overwrite it".
ATC: 916749481 - info@sulion.es / SAT : 916749483 - sat@sulion.es
FAN
Turn on / Turn off
OFF
Turn on / turn off light /
Change color temperature of the light.
2H
Natural wind (Speed cycle 1-6
progressive)
Self-temperature sensor
26ºC
Speed= 6
26ºC - 19ºC Speed= 3
4 4
<19ºC
Speed=1
Note: Press another button except
FAN
, 2h or
5 5
OFF
to exit the function.
6 6
Timer 2h
2H
Change sense of rotation
1
Speed 1
2
Speed 2
Speed 3
3
4
Speed 4
Speed 5
5
6
Speed 6
of the remote control for 5 continuous seconds.
11