MAINTENANCE
1.
Switch off the power supply. First switch off the appliance before disconnecting it from the mains.
2.
Clean with a soft, dry cloth.
3.
Use lukewarm water (below 40ºC) to clean if the appliance is very dirty.
4.
Never use volatile substances such as petrol or polishing powder to clean the appliance.
5.
Never spray water on the main unit, it is really dangerous!
It is necessary to clean the air filter after using it for about 100 hours. Clean it as follows.
1.
Stop the appliance and remove the air filter.
2.
Clean and reinstall the air filter.
3.
If the device is very dirty, wash it with a solution of detergent in warm water. 3-After cleaning, dry it in a
cool, shady place and reinstall it.
4.
Clean the air filter every two weeks if the device is operated in a high dust environment.
MAINTENANCE AFTER USE
1.
If the appliance is not going to be used for a long time, be sure to remove the primary and secondary
rubber plug from the drain hole to drain the water.
2.
Keep the appliance running with the fan only for half a day on a sunny day to dry the inside of the
appliance. Prevent mould and mildew.
3.
Stop the appliance and unplug it from the mains socket, then remove the batteries from the remote
control and store the appliance properly.
4.
Clean the air filter and reinstall it.
5.
Remove the air hoses and store them properly. Tightly plug the hole.
100
TROUBLESHOOTING
The following cases may not always be a malfunction.
Please check the suggestions below before requesting service.
It does not work
1.
If the protector trips or the fuse is blown.
2.
Please wait for 3 minutes and restart; the protective device may be preventing the unit from operating.
3.
If the batteries in the remote control are exhausted.
4.
If the plug is not properly connected.
Runs for a short time
1.
If the set temperature is close to the room temperature, you can reduce the set temperature.
2.
The air outlet is blocked by an obstacle. Remove the obstacle.
It works but does not cool
1.
If the door or the window is open.
2.
If there is another appliance operating with heat, such as a heater or a lamp etc...
3.
The air filter is dirty, please clean it.
4.
The air outlet or air inlet is blocked.
5.
The set temperature is too high.
Water leakage during movement.
1.
Drain condensate before moving.
2.
To avoid water leakage, place the unit on level ground.
Does not work and water is full (indicator E4)
3.
Remove the rubber stopper to drain the water.
4.
If you often find yourself in this condition, contact a qualified technician.