ENGLISH – Motorized screen user manual
The type of motor installed on the product is identified by a label applied on each product showing the CE logo. When unwrapping the product please check the model type indicated on the label in order to
perform the installation and cable connections correctly. Should the power of the motor be different from that of the supply network of the installation place, please contact an electrician to have a current and
Hz transformer installed.
electric cabling must be conformant with applicable IEC standards. IEC norm EN 60335-1 requires that supply
network be fitted with an omnipolar selector switch with contact opening distance of at least 3 mm. For the screen's
control use only the selector switch provided by manufacturer, or equivalent model, and follow the instructions of the
connection diagram shown on left (if the motor is mounted on the left, the colours of the wires must be inverted, i.e.
descending = brown, ascending = black). The selector switch must be mounted within sight distance of the product,
at a 1.5 - 1.8 m height from the floor. To connect the wires to the supplied switch, remove the plastic front plates to
Correctly performed, state-of-the-art, norm-compliant electrical connections are important to prevent accidents and
to ensure the screen's optimal and unaltered performance over time. Prior to carrying out any operation on electrical
parts ensure that power supply is disconnected. In screens fitted with cases the motor is positioned on the right-hand
side of the screen as seen from the front (upon request it can be located on the left). Never connect two or more
motors to the same selector switch without a control unit or two switches to the same motor..
electric cabling must be conformant with applicable IEC standards. IEC norm EN 60335-1 requires that supply network be fitted with an omnipolar selector switch
with contact opening distance of at least 3 mm. For each motor (e.g. plug switch etc.). In case of need, this device ensures that the power supply is safely and quickly
Correctly performed, state-of-the-art, norm-compliant electrical connections are important to prevent accidents and to ensure the screen's optimal and unaltered
performance over time. Prior to carrying out any operation on electrical parts ensure that power supply is disconnected.
Bus cables (black white orange) must be insulated if not used for the push-button command.
In screens fitted with cases the motor is positioned on the right-hand side of the screen as seen from the front.
Made by Adeo Screen sp. Z o.o. (Polska) Specifications are subject to change without notice. E&OE
Doc: ALUMID Installation Manual rev1 | 03.01.2014
Please verify that you are working with the latest revision of this document before specifying your screen.
09 MOTOR TYPE IDENTIFICATION –CHARACTERISTICS – ELECTRICAL CONNECTION
ELECTRICAL CONNECTION:
access the lock/unlock buttons
WARNING:
ELECTRICAL CONNECTION:
cut off. Use the wires as described in the figure.
WARNING:
Operates with standard radio control (supplied).
230V 50Hz
Motor characteristics:
Connection for each motor:
Frequency: ~Hz50
Power: 90W
Blue (Common)
Torque: 6Nm
Speed: 12Rpm
Brown (Up)
Max no. of cycles: 2
Cable length: 2.5m
Black (Down)
Mechanical strength:
EN14202 conformant
Yellow Green (Ground 230V)
Operating T°:
from –20 to +55 °C
120V 60Hz
Motor characteristics:
Connection for each motor:
Frequency: ~Hz60
Power: 80W
White(Common)
Torque: 88in.lb
Speed: 14r/min
Black (Down)
Max no. of cycles: 2
Cable length: 2.5 m
Red (Up)
Mechanical strength:
EN14202 conformant
Giallo verde (Terra 120V)
Operating T°:
from –20 to +55 °C
Somfy RTS 230V 50Hz
Technical characteristics:
Frequency: 433.92 MHz
Connection for each motor:
Brown (Phase 230V)
Blue (Neutral 230V)
Yellow Green (Ground 230V)
Frequency: ~Hz50
Power: 120W
Torque: 10Nm
Speed: 17Rpm
Max no. of cycles: 2
Cable length: 3m
Operating T°:
from –20 to +55 °C
Trans. range: 150mt