7 - SAFETY AND USE: PURPOSE OF USE AND USES TO BE AVOIDED
The SMART selector has been designed to select the operating mode of manusa automatic doors and to set up and adjust
the different operating parameters and functions. The warnings on this selector will be complemented and extended with
additional indications and warnings contained in the manual supplied with the automatic door, on which the selector is
mounted.
Below we list some of the uses to be strictly avoided:
- Do not modify the selector or any of its components.
- Do not allow children to play with the selector.
- Do not disconnect, manipulate or put out of service the doors' safety components.
- Do not use any spare parts which are not the original parts provided by manusa.
- Do not use the selector as a support element for objects or persons
- Do not, under any circumstance, open and manipulate the inside of the selector or its connections, unless this is
carried out by a manusa authorised service technician.
This list includes unintended uses which are reasonably foreseeable in connection with the use of this selector. However,
manusa is not responsible for any possible accidents or damage caused by any other misuse not listed above.
8 - MALFUNCTIONS
Should the supervising program detect malfunctions in the operation of the door, the screen will show a
code number accompanied by a malfunction icon:
Should a malfunction message appear on the display, in most cases, you may clear this malfunction code
and resume normal operation by choosing the OPEN operating mode on the selector, followed by the
AUTOMATIC mode.
Should the malfunction persist after performing this operation, please contact manusa's Technical Service.
MALFUNCTION
POSSIBLE CAUSE
a. Mains overcurrent
OVERCURRENT
b. Short circuit in motor or
0001
circuit.
Overcurrent in motor
SOS
a. Panic break-out leaves
open.
0002
b. Emergency push button
activated.
Emergency signal activated
OBST CLOSING
Obstruction
closing cycle.
0003
Obstruction on closing
OUTSIDE KEY
The outside key switch has
not been removed from the
SWITCH
device.
0004
Outside key switch activated
DOOR PARAM MEM.
Parameter
falling.
0005
Parameters memory
OBST. OPENING
Obstruction
opening cycle.
0006
Obstruction on opening
PHOTOCELL
The IR barriers are blocked
for a period > 1'.
0008
IR barriers
FIRE ALARM
Fire alarm signal activated.
0009
Infrared barriers
LOW BATTERY
a. Low battery.
b. Low mains voltage.
0011
Panic door system
SOLUTION
Change to OPEN followed
by AUTOMATIC mode to
resume normal operation. If
the problem persists, call
the Technical Service.
a. Check position of panic
break-out leaves.
b. Check the emergency push
button.
within
the
Check and remove any obs-
truction within the door closing
cycle. Then resume by chan-
ging
the
door
to
OPEN
followed by AUTOMATIC
mode
Remove the key from the
outside key switch device.
memory
is
Call Technical Service.
within
the
Check and remove any obs-
truction within the door opening
cycle. Then resume by chan-
ging
the
door
to
OPEN
followed by AUTOMATIC
mode
Check the alignment of the
IR barriers.
Check fire alarm system.
If the door was disconnec-
ted, leave the door connec-
ted during 24 hours to
charge the batteries. If the
warning persists, call the
Technical Service.
MALFUNCTION
POSSIBLE CAUSE
INSIDE RADAR
Radar contact permanently
closed for a period of > 1'.
0012
Malfunction in internal radar
OUTSIDE RADAR
Radar contact permanently
closed for a period of > 1'.
0013
Malfunction in external radar
PHOTOCELL 3
The thid IR barrier is bloc-
ked.
0014
IR Barrier 3
MOTOR CONTROL
Malfunction in the control
board.
0015
Malfunction in the motor control
SAFETY SENSOR
Safety
activated.
0016
Malfunction on side sensors
The LCD screen
The selector has no power.
does not light up
LOADING DATA
No communication with the
operator.
----
Communication fault occurs
when the following message
appears on screen:
"loading data"
10
SMART SELECTOR WITH LCD - USER MANUAL
SOLUTION
Call Technical Service.
Call Technical Service.
Call Technical Service.
Change to OPEN followed
by AUTOMATIC mode to
resume normal operation. If
the problem persists, call
the Technical Service.
opening
signal
Verify that there is no object
within the sensor detection
area.
Check door power supply.
Call Technical Service.