HI-PRO LED A23, A25 LAMPS
Models: S13100, S13101, S13102, S13103, S13104, S13105
S13106, S13107, S13108, S13109, S13110, S13111
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing fixture. Retain for future reference.
CAUTION: IF THE LAMP OR LUMINAIRE EXHIBITS UNDESIRABLE OPERATION (BUZZING, FLICKERING, ETC.), IMMEDIATELY TURN
OFF POWER, REMOVE LAMP FROM LUMINAIRE AND CONTACT THE MANUFACTURER. DO NOT USE IF PRODUCT IS DAMAGED.
WARNING: Risk of Fire or Electric Shock.
• LED Retrofit Kit installation requires knowledge of luminaire electrical systems. Installation should be performed by a qualified electrician.
• Install this lamp only in the luminaires that have the construction features and dimensions written and shown in the drawings and where
the input rating of the lamp does not exceed the input rating of luminaire.
• To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
• Disconnect power at the source before installation, inspection or removal.
• This item is rated at 100-277V.
• Not intended for use with emergency exit fixtures or emergency exit lights.
• Not for use with luminaire ballast.
• This lamp is non-dimmable. Not for use with dimmer.
• Do not make or alter any open holes in an enclosure of wiring or electrical components during lamp installation.
• "This luminaire has been modified to operate LED lamps" shall be marked on the retrofit luminaire where readily visible by the user during
normal maintenance including re-lamping.
• Risk of fire or electric shock. Do not open or modify.
• Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead
installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires
by employing applicable connections.
• Suitable for damp locations. Suitable for use in wet locations when used in an outdoor-rated fixture. Not for use where directly exposed
to the weather or water.
INSTALLATION: Retrofit Bollard Fixture
1. Turn off power, unscrew the light cover from bollard.
2. Forward the light cover, facing the light socket, loosen
the screw, and remove the lamp.
3. Screw lamps in the socket, fix the light socket to
the light cover again.
4. Put the light cover back on the fixture, fasten the screw.
© Copyright 2019 Satco Products, Inc. 1/19
Post Top Fixture
1. Turn off power to the fixture. Remove
existing HID lamp from the fixture,
and screw lamp into the socket.
3. Close the fixture's junction box.
Clean the area before applying
the lamp warning label to a visible
location on the fixture.
WARNING LABEL – Reference
for disposal in accordance with
European defaults used electrical
and electronics devices must be
recyled.The symbol of the waste
bin on wheels refers to the
necessity of separate collection.
GUIDELINE 200/96/EG of the
EUROPEAN PARLIAMENT AND
the COUNCIL of January 27, 2000.
2. Open the fixture's junction box
and bypass the HID ballast,
ignitor and the capacitor by
disconnecting the line and
neutral wires and socket black
and white wires in the locations
with "X" marks. See schematic
diagram below.
N(L1)
N(L1)
Satco Products, Inc.
Brentwood, NY 11717