LED AREA LIGHT, 120-347V
Models: 65-850, 65-851, 65-852, 65-853, 65-854,
65-855, 65-856, 65-857, 65-858, 65-859
INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing fixture. Retain for future reference.
WARNING:
• To reduce the risk of personal injury or property damage
from fire, electric shock, falling parts, cuts/abrasions,
and other hazards read all warnings and instructions
included with and on the fixture and all fixture labels.
• Commercial installation, service and maintenance of
luminaries should be performed by a qualified licensed
electrician. For the installation: If you are unsure about
the installation or maintenance of the luminaries, consult
a qualified licensed electrician and check your local
electrical code.
• Turn OFF electrical power at fuse or circuit breaker before
wiring fixture to the power supply.
• Turn OFF the power when you perform any maintenance.
• All connections should be capped with UL approved
wire connectors.
• Verify that supply voltage is correct by comparing it with
the luminaire label information.
• Can be used for outdoor installation.
ELECTRICAL REQUIREMENTS
Item Number
65-850
100W LED AREA LIGHT TYPE III
65-851
100W LED AREA LIGHT TYPE III
65-852
150W LED AREA LIGHT TYPE III
65-853
150W LED AREA LIGHT TYPE III
65-854
200W LED AREA LIGHT TYPE III
65-855
200W LED AREA LIGHT TYPE III
65-856
240W LED AREA LIGHT TYPE III
65-857
240W LED AREA LIGHT TYPE III
65-858
300W LED AREA LIGHT TYPE III
65-859
300W LED AREA LIGHT TYPE III
© Copyright 2021 Satco Products, Inc. 9/21 v1.0
Description
INSTRUCTIONS:
• This product has dimming and non-dimming function,
which differs in installation ways.
• The dimming function available for this fixture is
1-10VDC dimming.
• Choose the wire connection, dimming and installation
variations, according to your needs and fixture
purchased.
Voltage/CCT/Finish
120-347V/4000K/BRONZE
120-347V/5000K/BRONZE
120-347V/4000K/BRONZE
120-347V/5000K/BRONZE
120-347V/4000K/BRONZE
120-347V/5000K/BRONZE
120-347V/4000K/BRONZE
120-347V/5000K/BRONZE
120-347V/4000K/BRONZE
120-347V/5000K/BRONZE
1
Frequency
Rated Current
1.1A
1.1A
1.65A
1.65A
2.2A
50/60Hz
2.2A
2.64A
2.64A
3.3A
3.3A
Satco Products, Inc.
Brentwood, NY 11717

Publicidad

loading

Resumen de contenidos para Satco NUVO 65-850

  • Página 1 240W LED AREA LIGHT TYPE III 120-347V/5000K/BRONZE 2.64A 65-858 300W LED AREA LIGHT TYPE III 120-347V/4000K/BRONZE 3.3A 65-859 300W LED AREA LIGHT TYPE III 120-347V/5000K/BRONZE 3.3A © Copyright 2021 Satco Products, Inc. 9/21 v1.0 Satco Products, Inc. Brentwood, NY 11717...
  • Página 2 WIRING DIAGRAM NOTE: For additional wiring diagrams with and without photocell and/or motion sensor, see page 10. Confirm wire colors of DIM + and DIM – with lamp label. OPTIONAL BRACKETS FOR INSTALLATION NOTE: There are 7 optional brackets for this fixture. See pages 3-9 for installation instructions.
  • Página 3 INSTALLATION: Slip-Fitter Mount STEP 1: Unscrew to remove the cover of junction box STEP 2: Assemble the slip-fitter bracket on the pole, of slip-fitter bracket, pass the wires out from pole tighten the fixing screws to lock with a wrench. through slip-fitter bracket.
  • Página 4 INSTALLATION: Adjustable Arm Mount STEP 1: Unscrew to remove the cover of junction box STEP 2: Assemble the adjustable arm bracket on the of adjustable arm bracket, pass the wires out from pole pole, tighten the fixing screws to lock with a wrench. through adjustable arm.
  • Página 5 INSTALLATION: Fixed Arm Mount (continued) STEP 4: When installing to a square or round pole, align the holes of the fixed arm bracket and pole, pass the fixing screws through both holes, then put iron bar inside of pole to attach with fixing screws. NOTE: When installing to a round pole, remove the rubber gasket.
  • Página 6 INSTALLATION: Trunnion Mount STEP 1: Mark the fixing hole STEP 2: Knock the two STEP 3: Fix the trunnion bracket locations on the wall with trunnion expansion bolts into wall on the mounting surface by bracket, then drill the holes 10mm with a hammer.
  • Página 7 INSTALLATION: Slip-Fitter Long Arm Mount STEP 1: Loosen the fixing screw on the bracket with STEP 2: Pass fixture’s AC input wires through bracket A a wrench to release the bracket holder. Remove the and assemble bracket A to the fixture body with screws. screws from the junction cover of bracket holder.
  • Página 8 MOTION SENSOR INSTALLATION: Slip-Fitter Long Arm Mount Punch out the motion sensor knock-out on the slip-fitter long arm bracket with a hammer. Follow STEPS 1 & 2 on page 7. Install motion base and waterproof gasket on the slip-fitter long arm bracket, then tighten screws. Screw the Screw the microwave or infrared sensor into sensor base.
  • Página 9 INSTALLATION: Fixed Adapter Arm Mount (continued) STEP 6A: Push the connected wires inside of the pole, STEP 6B: Push the connected wires into fixed adapter close the pole’s top cover, then close the junction box cover. arm junction box, close the box cover, then close the poles top cover.
  • Página 10 MOTION SENSOR INSTALLATION: Fixed Adapter Arm Mount Punch out the photocell knock-out on the fixed adapter arm bracket with a hammer. Follow STEPS 1 – 4 on page 8. Install motion base and waterproof gasket on the fixed adapter arm bracket, then tighten screws. Screw the microwave or infrared sensor into sensor base.
  • Página 11 PARAMETER SETTING BY DIP SWITCH See diagrams below for settings: 1, 2 set Detection Range; 3, 4 set Hold-Time; 5, 6 set Light-Control; 7, 8 set Stand-by PARAMETER SETTING BY DIP SWITCH PARAMETER SETTING BY DIP SWITCH PARAMETER SETTING BY DIP SWITCH Light Level;...
  • Página 12 LUZ LED DE ÁREA DE 120–347V ESPAÑOL: Modelos: 65-850, 65-851, 65-852, 65-853, 65-854, INSTRUCCIONES DE INSTALACIÓN Y SEGURIDAD 65-855, 65-856, 65-857, 65-858, 65-859 IMPORTANTE: Lea esto antes de instalar el accesorio. Consérvelo para referencia futura. ADVERTENCIA • Para reducir el riesgo de lesiones personales o daños a la propiedad a causa de incendio, descarga eléctrica, piezas que caen, cortes/ abrasiones y otros peligros, lea todas las advertencias e instrucciones incluidas con y en el accesorio y todas las etiquetas del accesorio.
  • Página 13 INSTALACIÓN: Montaje de la Unión (Consulte los diagramas en la página 6) PASO 1: Afloje los tornillos en ambos lados del soporte mediante una llave, ajuste el ángulo del soporte de la unión para mantenerlo paralelo con respecto a la superficie de instalación. PASO 2: Marque en la pared donde se ubica el orificio de instalación usando el soporte de la unión, después, con un taladro eléctrico perfore orificios de 10 mm de diámetro.
  • Página 14 Configurar el Tiempo de Retención Se puede configurar que la luz permanezca encendida por cualquier periodo de tiempo entre aproximadamente 10 segundos y un máximo de 60 minutos. Cualquier movimiento que se detecte antes de que transcurra este tiempo volverá a iniciar el temporizador. Se recomienda seleccionar el tiempo más corto para ajustar la zona detección y llevar a cabo una prueba de caminata.
  • Página 15 ÉTAPE 4: Lorsque vous installez une pôle carrée ou ronde, alignez les trous du support à bras fixe et de la pôle, faites passer les vis de fixation à travers les deux trous, puis mettez la barre de fer à l’intérieur de la pôle et utilisez les vis de fixation. REMARQUE: Lorsque vous installez une pôle ronde, retirez le joint en caoutchouc.
  • Página 16 INSTALLATION DE LA PHOTOCELLULE, OPTION 2: Support à Bras à Adaptateur Fixe (Voir les diagrammes à la page 9) Fixez la plaque de la photocellule au support à bras à adaptateur fixe et dévissez avec un tournevis pour retirer la plaque de la photocellule. Suivez les ÉTAPES 1 à...