Descargar Imprimir esta página

Absolute OF-S90 oilfree Manual Del Usuario página 17

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3.5 The compressor stops while working
The motor has an automatic resetting thermal protection, that stops the compressor
·
when the temperature is too high. The compressor will start again automatically after
15/20 minutes.
·
3.6 Air leaks
Can be due to bad seal of any connection, check all connections wetting with suds
·
·
3.7 Leak from the valve placed under the pressure switch
Damaged valve, replace it.
·
The defect can be due to an unperfect valve seal (See point 3.1d).
·
3.8 The compressor starts when no air is being tapped
Air leak (See point 3.6).
·
5.9 The compressor starts and stops more frequently than usual
a) Large amount of condensate in air tank. Remove condensate.
·
b) Air leak (See point 3.6).
·
3.10 The compressor does not switch on when pressure is under the minimum level
and/or does not switch off at max pressure
Defective pressure switch. Replace.
·
3.11 The compressor gets very hot
a) Air leak (See point 3.6).
·
b) Clogged intake filter. Clean or replace.
·
c) Too high outsidet temperature. Do not close the unit in a cupboard unless ade-
·
quately ventilated.
d) Over-running.
·
Ensure the compressor is the correct model for your work load.
All manuals and user guides at all-guides.com
GB
15

Publicidad

loading