Descargar Imprimir esta página

Husqvarna HH42 Manual Del Operador página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation Location to Reduce the Risk of Fire
WARNING! Exhaust heat/gases could ignite
combustibles, structures or damage fuel tank
causing a fire, resulting in death or serious injury.
• Pressure washer must be at least 5 ft. (1.5 m) from any
structure, overhang, trees, windows, doors, and any wall
opening, shrubs, or vegetation over 12 in. (30.5 cm) in
height.
• Do not place pressure washer under a deck or other type
of structure that may confine airflow. Smoke alarm(s)
must be installed and maintained indoors according to
the manufacturer's instructions /recommendations.
• Carbon monoxide alarms cannot detect smoke.
• It is a violation of California Public Resource Code
Section 4442, to use or operate the engine on any forest-
covered, brush-covered, or grass-covered land unless
the exhaust system is equipped with a spark arrester, as
defined in Section 4442, maintained in effective working
order. Other states or federal jurisdictions may have
similar laws, reference Federal Regulation 36 CFR Part
261.52.
• Contact the original equipment manufacturer, retailer,
or dealer to obtain a spark arrester designed for the
exhaust system installed on this engine.
• Replacement parts must be the same and installed in the
same position as the original parts.
5 ft (1.5 m) min.
MUFFLER
5 ft (1.5 m)
min.
Step 2: Oil and Fuel
Check Oil Level
1. Make sure pressure washer is on a level surface.
2. Refer to engine operator's manual and follow oil and
fuel recommendations and instructions.
Transporting
Do not tip engine or equipment at an angle which causes
fuel to spill.
Step 3: Set Up
Clean Debris
Clean any accumulated debris. Keep area around muffler
free from any debris.
• Use a soft bristle brush to loosen caked on dirt or oil.
• Use a damp cloth to wipe exterior surfaces clean.
Lubricate O-rings
Lubricate all connections shown to extend the life of the
o-rings.
1. Inspect and clean connecting surfaces prior to
lubrication and assembly. Replace o-rings that are
damaged or missing. See Common Service Parts.
Spray Gun
High Pressure Hose
NOTICE Never repair leaking connections with sealant of
any kind. Replace o-ring.
2. Use a small brush or cotton swab to apply a light
coating of grease directly to o-rings.
High Pressure Outlet
Spray Wand
7