Fig. 1a
Fig. 1d
A = Thermal radiation field (900 mm) with fixed model
B = Distance to wall at least 100 mm with non-
combustible and combustible wall coverings
C = Thermal radiation field with rotary model (900 mm)
D = Distance to wall at least 515 mm with non-combu-
stible and combustible building materials
Fig. 1b
Fig. 1e
E = Distance to wall at least 855 mm with non-
combustible and combustible wall coverings
F = Distance to wall at least 130 mm with non-
combustible and combustible wall covering
G = Distance to wall at least 470 mm with non-
combustible and combustible wall covering
GB 9
Fig. 1c
Fig. 1f
H = Floor covering made out of non-combustible buil-
ding materials with the fixed model
I = Floor covering made out of non-combustible buil-
ding materials with the rotary model
J = Radiation protection plate
Fig. 1g