lt is recommended to leave a space of 50 cm from the top, 15 cm from the sides, 40 cm
from the bottom where the assembly of the boiler is to be made.
The condensing water outlet should be made with a 2 degree slope going downward and
connected to the waste water drain. The waste hose must be insulated against frost.
For water connections, filter and ball valve must be fitted to the boiler inlets. (Fig. 5)
The mains input must not exceed the 8 bar pressure limit. The pressure reducer must be
installed in cases of higher mains pressure.
The suitability of the gas installation and the device should be checked.
WARNING: In order not to damage the condensation trap during the installation of the
combi boiler, do not place it upright after it has been removed from the packaging
carton.
Safety Valve
Hea�ng Flow connec�on
WARNING: Siphon and safety valve connection must be given to the
installation drainage line.
Figure.5
Gas Connec�on
Water outlet connec�on
Water inlet
connec�on
23
Condensate
Siphon
Hea�ng return
connec�on