7.1. Before using
Notice:
-
Operation temperature range:
DB/WB(ºC)
DB/WB(ºC)
Check up whether the exhaust hose has been mounted properly.
Cautions for cooling and dehumidifying operations:
– When using functions on cooling and dehumidifying, keep an interval of at least 3 minutes
between each ON/OFF.
– Power supply meets the requirements.
– The socket is for AC use.
– Do not share one socket with other appliances.
– Power supply is AC220--240VV, 50Hz.
7.2 Dehumidifying operation
Press the "Mode" button till the "Dehumidify" icon appears .
– Automatically set the selected temperature to current room temperature minus 2ºC.
(16ºC-31ºC).
– Automatically set the fan motor to LOW wind speed.
7.3 Cooling operation
Press the "Mode" button till the "Cool" icon appears.
– Press the " DOWN "or" UP "button to select a desired room temperature. (16ºC-31ºC).
– Press the " WIND " button to select wind speed.
7.4 Fan operation
– Press the "Mode" button till the "Fan" icon appears.
– Press the " WIND" button to select wind speed.
7.5 Heating operation
– Press the "Mode" button till the "Heat" icon appears.
– Press the " DOWN "or" UP " button to select a desired room temperature (16ºC-31ºC).
– Press the " WIND " button to select wind speed.
Maximum cooling
35/24
• •
Maximum heating
1
27/---
27
Minimum cooling
18/12
Minimum heating
7/---