IMPIANTO ELETTRICO - ELECTRICAL SYSTEM - SYSTÈME ÉLECTRIQUE - ELEKTRISCHE ANLAGE -
INSTALACIÓN ELÉCTRICA - ЭЛЕКТРИЧЕСКАЯ СИСТЕМА - ΗΛΕΚΤΡΙΚΗ ΜΟΝΑΔΑ -
A - SHOWER HEAD CONTROL UNIT
•
Install in the safety zone: Z1
•
Power: 24 W
•
Input: 12 V dc, 2 A (max)
•
Output:
1.
LED: RGB+W IP67 12V dc (power 22 W (max);)
2.
KEYBOARD: connector IP67 - PG7
3.
PRESENCE SENSOR "PIR": connector IP67 - PG7
4.
Serial Port (RS485): connector IP67 - PG7
•
Service temperature: 0°C÷50°C
•
Protection: IP66
B - REMOTE CONTROL
•
Install in the safety zone: Z1-Z2-Z3
•
Protection: IP66
•
Battery: CR2032
C - POWER SUPPLY (can be ordered as come optional)
•
Install in the safety zone: Z3
•
Input: 100-240 V ac, 0.59÷0.29 A, 50÷60 Hz
•
Output: 12 V dc, 2 A (max)
•
Standard: EN60950-1
D - CAPACITIVE KEYBOARD CONTROL (can be ordered as come optional)
•
Install in the safety zone: Z1-Z2-Z3
E - TRADITIONAL CONTROL (no order possible)
•
Install in the safety zone: Z3
To install the led control in the safety zone Z3, the capacitive keyboard control can be excluded in favor of a traditional control, equipped with
at least two buttons, with the finish plate meeting the specific requirements of the customer. A solution conceived to offer the largest choice of
shapes, finishes and materials.
WARNING: the two solutions proposed for the installation of the led control can be associated, giving the possibility of two controls, one inside
the shower tray and the other in the bathroom.
F - POWER SUPPLY/CONTROL UNIT PER SENSOR PIR (can be ordered as optional)
•
Install in the safety zone: Z3
•
Power: < 1 W
•
Input: 230 V ac
•
Safety: IP20 / II / CE
•
Service temperature: -25°C÷50°C
G - PRESENCE SENSOR "PIR" (can be ordered as come optional)
•
Install in the safety zone: Z1-Z2-Z3
•
Safety: IP65 / II / CE
•
Service temperature: 0°C÷45°C
Serial Port (RS485) - Connection for communication kit (to order as an option) between two or more synchronized control units, in the
MASTER-SLAVE configuration
•
Connection between A-C
Length max = 8 m
Poles = 2
Section = 20-22 AWG
•
Connection between A-D
Length max = 7 m
Cable diameter: 4÷6 mm
Poles = 6
Section = 24 AWG
•
Connection between A-E
Length max = 7 m
Cable diameter: 4÷6 mm
Poles = 3 (GND common)
Section = 24 AWG
•
Connection between A-F
Length max = 10 m
Cable diameter: 4÷6 mm
Poles = 2
Section = 20 AWG
•
Connection between A-Serial Port (RS485)
Length max = 10 m
Cable diameter: 4÷6 mm
Poles = 2
Section = 20 AWG
WARNING:
- the connection to a cut out switch with intervention current not greater than 30mA is mandatory.
- on the supply cable "L+N" (not included), to guarantee compliance with the requirements of Electromagnetic Compatibility, it is
necessary to position the following ferrite: Trademark: Fair-Rite Products Corp - Model: 431164281 or a component with similar
characteristics.
DATA FOR THE ELECTRICAL SYSTEM
ELECTRICAL CONNECTIONS DATA
25
电气设备