OPERATION
Do not throw items into the storage area. Failure to heed these
recommendations could result in damage to the interior of the
cabinet.
DANGER
E
CAUTION
REFRIGERATION CYCLE
Refrigerators: Every 6 hours, the unit will shut off to allow the evaporator coil to defrost and the
controller will display the defrost symbol When the coil temperature reaches 41°F or after 20
minutes, the unit returns to the refrigeration cycle The factory setting for temperature range is
28° to 34°F
Freezers: During the refrigeration cycle the controller supplies power to the condensing unit
and evaporator fan motors The evaporator fans will run at any time when the evaporator coil
temperature is below 35°F and they will cycle off during defrost period Every 6 hours, the unit
will shut off and the defrost heater will defrost the evaporator coil and the controller will display
the defrost symbol When the coil temperature reaches 45°F or after 20 minutes, the unit returns
to the refrigeration cycle
1 Anti-Condensation heaters on the door frames work in conjunction with the compressor
2 The factory setting for temperature range is -7°F to -3°F
On/Off Switch:
An on/off switch is located on the front of the bottom shroud When the unit is on, the switch
will glow green
Light Switch:
A light switch is located next to on/off switch on the front of the bottom shroud