Technical data for the plumbing system:
- Minimum working pressure: 2 bar
- Working pressure: recommended operating field 2 ÷ 4 bar
- Maximum working pressure: 5 bar (Install a pressure reducer for higher hydraulic pressures)
- Maximum working temperature: 65°c
- Floor waste required with capacity ≥ 40 l/min.
- 11 kg empty weight of the complete head shower (with water about 12,3 kg)
Supply pipe to shower head [ A ]: minimum internal diameter 12mm
Static
pressure
[ bar ]
2
3
4
5
( * ) Minimum delivery from head shower for the correct working "Rain": 16 l/min [ B ].
Static
pressure
[ bar ]
2
3
4
5
Data for plant dimensioning
Minimum required feeding
for a correct working of the shower system*
Data for boiler and waste dimensioning
Maximum delivery for the shower system
fed with internal 12 mm Ø pipes
14
[ l/min ]
26,5
21,5
19,5
19
Rain Function [ B ]
[ l/min ]
19 [ with limiter ]
19 [ with limiter ]
19 [ with limiter ]
19 [ with limiter ]