2. Excessive dirt on glass
3. Glass bleaching or colour
fading of the plate
4. Poor heating
5. Venting smoke and / or
gases from the front, bad
smell
6. Excessive draft
7. Poor draft
7. CE INFORMATION
The CE label is located under the appliance. This label contains technical data and OF number. (This number can
also be found in the guarantee).
THIS NUMBER IS ESSENTIALFOR ORDERING SPARE PARTS.
CAUTION:
-
All tests are carried out in observance of Regulations
UNE-EN13240:2002-A2:2005-AC: 2006-A2:2005/AC: 2007 "Stoves that use solid fuels –
Requirements and test methods".
-
The review of the equipment, the installation and ducts must be carried out by a professional.
-
In case of doubt regarding the described herein, please contact your Rocal dealer.
-
FAILURE TO COMPLY WITH THE OBLIGATIONS DESCRIBED HEREIN OR IMPROPER HANDLING OF THE EQUIPMENT SHALL EXONERATE
THE MANUFACTURER OF ANY LIABILITY.
11
Incorrect duct
Inappropriate fuel
Overly closed registers
Excessive temperature caused by excessive heat in
the combustion chamber
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong position
First lighting
Flammable or combustible items in the enclosure or
surrounding walls of the equipment
Crack in the combustion chamber of the equipment
Incorrect duct
Combustion control registers in the wrong position
Incorrect duct
Duct dirtiness
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
Check the fuel load avoiding overheating
Adjust registers
Use recommended fuel
Adding fuel
Adjust registers
Wait for the polymerization process of the paint to finish;
this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and replace
them.
Check for tightness and if you discover a crack, please
contact your dealer.
Duct servicing
- Excessive length (Install upper baffle plate following
steps "C.7", "C.8", "C.9", "C.10", "C.11", "C.12", "C.13"
and "C.14")
- Check Depression
- Incorrect diameter
- Check door gasket
Open the primary and secondary register following the
steps outlined in the manual. Should this not have an
effect, check that the flue duct is clean; if it is not clean,
contact a professional to clean this. If the problem persists
contact your dealer.