Descargar Imprimir esta página

Honeywell HGI 80 Instrucciones De Montaje página 7

Publicidad

HGI 80
GB
6.
Technical Data
Operational Environment
Environmental temperature
Air humidity
Storage:
Storing temperature
Air humidity
Housing protection
Size of the housing (socket + cover)
RF communication:
Frequency
Tolerance
Deviation
Input Ratings
max. current (low power device)
max. power consumption according to USB
specification
Input VCC
Inrush current
Data lines (D+, D-)
Cable Type
Data Transmission
Required Software Version HCM 200 D
0 – 50 °C
5 – 93 % not condensing
–35 – +70 °C
5 – 95 % not condensing
IP 30
90 x 90 x 28 mm
868.3 MHz
+/–20 kHz
+/–50 kHz
100 mA
5 V x 100 mA = 500 mW
typically 5 V DC, min. 4,4 V; max. 5,25 V
deltaVCC max. 330 mV (max. 10 uF II 44 Ohm)
High: nominal 3,3 V; min 2,0 V
Low: nominal 0 V; max 0,8 V
USB cable length max. 5 m type B
NOTE: The HGI 80 is compatible with the full speed USB 2.0
specification however the USB interface transmits at a baudrate
of 115 kbaud.
7.0 or higher