Power
cord
Pump
connection
cord
Automatic control coupling
• Attach the automatic control (A) to the pump outlet with
a coupling nut (B) and tighten it by hand.
• Turn the automatic control to the required position and
tighten the coupling nut.
• Connect the outlet of the automatic control to the
pressure line (outlet) using a flexible hose (C).
• Connect the automatic control to the pump and then to
the socket (D).
A
C
6
ENGLISH
• For domestic use it is recommended to use a grounded polarized plug for pump
operation.
B
Wiring
L
N
U
V
Installation
• In case of using submersible pumps (E), fixed piping
must be used at the control outlet (F) and flexible hose at
the inlet (G).
F
D
G
E