aquatermic AQ OUT HY 40 Manual De Usuario página 34

Publicidad

Idiomas disponibles

Idiomas disponibles

content
symbol
division
symbol
Malfunction of
H
driven board of
fan (unified)
Preheat time
U
for compressor
is insufficient
Communication
Debugging
malfunction for
type
indoor unit,
C
outdoor unit
and wired
controller of
indoor unit
Standby
A
debugging of
unit
Status
SE operation
n
setting for
system
Content
symbol
Division
symbol
L
Mode shock
Indoor
Malfunction of
outlet tube
d
temperature
sensor
E
Malfunction of
discharge
F
temperature
sensor for
compressor 2
Overcurrent
J
protection
compressor 6
Malfunction of
inlet
Outdoor
temperature
b
sensor 1 for
gas-liquid
separator
Driven IPM
module of
P
compressor
protection
Driven IPM
module
H
protection for
fan
0
1
Abnormal
operation of
driven board
of fan
(unified)
Operation
parameters
inquiry for
compressor
Defrosting
period K1
setting
6
7
No master
indoor unit
Malfunction of
humidity
temperature
sensor
Malfunction of
discharge
temperature
sensor for
compressor 3
Gas-mixing
for
protection
4-way valve
Malfunction of
inlet
temperature
sensor for
gas-liquid
separator
Malfunction of
driven
temperature
sensor of
compressor
Malfunction of
driven
temperature
sensor of fan
2
Voltage
Reset
protection of
protection of
driven board of
driven board of
fan (unified)
fan
Wrong setting
for capacity
Power phase
code of outdoor
protection
unit/jumper cap
Communication
Communication
malfunction
malfunction
between
between
master unit and
master unit and
driven board of
driven board of
inverter
inverter fan
compressor
Refrigerant
recovery
Defrosting
operation
Upper limit for
capacity
collocation ratio
Compulsory
of indoor unit
defrosting
and outdoor
unit setting
8
Quantity of
indoor units for
Power supply
one-to-more
is insufficient
units is not
uniform (HB net
work)
Malfunction
water
Malfunction of
temperature
jumper cap
sensor
Malfunction of
Malfunction of
discharge
discharge
temperature
temperature
sensor for
sensor for
compressor 4
compressor 5
High pressure
Low
for
ratio protection
ratio protection
Malfunction of
Malfunction of
gas outlet
outdoor
temperature
humidity
sensor of heat
sensor
exchanger
High
Desynchronizing
temperature
protection of
protection for
inverter
driven IPM of
compressor
compressor
High
Desynchronizing
temperature
protection of
protection for
inverter fan
driven IPM of
30
3
4
Driven PFC
protection for fan
Refrigerant-lacking
protection
Malfunction of
indoor unit-lacking
Oil return
Maximum output
capacity limit
setting
9
A
Series of
indoor units for
one-to-more
units is not
uniform (HB
net work)
Abnormal
network
address for
indoor unit
Malfunction of
discharge
temperature
sensor for
compressor 6
Abnormal
pressure
pressure
protection
Malfunction of
oil return
temperature
sensor
Malfunction of
driven storage
chip for
compressor
Malfunction of
driven storage
chip of fan
5
Overcurrent
protection of
inverter fan
Wrong
addressing for
driven board of
compressor
Alarm because
of engineering
code shock of
indoor unit
On-line test
Compulsory
deviation for
indoor unit's
engineering
series number
H
Air quality is
bad
PCB board of
wired
controller is
abnormal
Current
sensor for
compressor 1
is abnormal
Clock time of
system is
abnormal
High voltage
protection for
driven DC bus
bar of
compressor
High voltage
protection for
driven DC bus
bar of fan