2.1 Names of Main Parts
No.
①
Name
Motor
2.2 Combinations of Indoor and Outdoor Units
(1) The total capacity of indoor units should be within 80%~100% of that of outdoor units. See below the
number of indoor units that can be connected to one outdoor unit:
Model
AQ OUT HY 40
AQ OUT HY 45
AQ OUT HY 54
(2) Select outdoor unit, hydro box and water tank:
Outdoor unit
AQ OUT HY 40
AQ OUT HY 45
AQ OUT HY 54
(3) It can perform air conditioning function only or perform air conditioning with water
heating or floor heating function. Water heating function are realized through the hydro box or hot
water converter. Floor heating function is realized through the hydro box .Indoor unit can be a
high-efficiency duct type unit, wall-mounted type unit, one-way cassette type unit, residential
standard static pressure duct type unit, etc. If indoor unit or hydro box or hot water converter
receives operation command, then outdoor unit will operate according to capacity demand. If indoor
unit and hydro box or hot water converter both stop operation, outdoor unit will stop as well.
②
Fan blade
Hydro box
Applicable water tank
Hydro box
Water Tank
AQUABOX 16
AQ OUT HY 40
AQ OUT HY 45
AQ OUT HY 54
Fig.1
③
Electric box
High pressure gas
assembly
pipe valve
Sets of connectable
indoor units
2~6
2~7
2~8
Air conditioning + Water heating + Floor heating
3
④
⑤
Gas pipe
valve
Remark
Function
⑥
Liquid pipe
valve