2 A CUTOUT FOR STEAM OVENS IN WALL CABINET
NOTE: If the cabinet does not have a front frame and the sides are less than 3/4" (1.9 cm) thick, shim both sides
equally to establish the cutout width.
E
Side-by-Side Installations
Install two ovens in separate cutouts.
Center Line
Center Line
30.5" (77.5 cm)
Cutout –
Cutout –
observe all
observe all
dimensions and
dimensions and
requirements.
requirements.
Junction Box Location
Junction Box
allowed if flush
1"
3-3/4"
14"
Junction Box not allowed in this space
4
Installation Instructions
Opening
Between
Inside Walls
Must be at
Least 28-1/2"
(72.4 cm)
Wide
5-1/8" (13 cm) Min.
Preferred Junction
Box location
2-1/4"
1-3/4"
Junction Box
Location (see
detail below)
D
Cutout Depth
23-1/2"
(59.7 cm) Min.
NOTE: Allow
1/4" (0.64 cm)
clearances from
side edges of
oven door.
Dimension
Dimension
Description
A
Cabinet Width
B
Cutout Width
C
Cutout Height
D
Clearance from cutout -
side edges*
E
Clearance to Adjacent
Corners, Drawers,
Walls, etc., When Door
Is Open
F
Clearance from cutout
- top*
G
Clearance from cutout -
bottom*
H
Junction Box Location
* Refers to minimum clearance required for wall oven installation and does not reflect actual
product dimensions.
B
F
C
G
Recommended
Cutout Location
from Floor
42" (106.68 cm)
A
30" Steam Oven
30" (76.2 cm)
25-1/4" (64.1 cm) min.
25-3/4" (65.4 cm) max.
17-1/2" (44.4 cm) min.
17-3/4" (45.1 cm) max.
2-1/4" (5.7 cm)
13" (33 cm) min.
1" (2.5 cm) min.
3/4" (1.9 cm)
see detail
right side preferred
31-2000694 Rev. 1