Descargar Imprimir esta página

Astralpool Command Connect Compact Manual De Instalación Y De Uso página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 9
4
The box is now operational and can be controlled using the iAquaLink+® app.
6. Main functions of the "Smart Relay"
The Smart Relay embedded in the Command Connect cabinets is dual channel and used to:
• Control the pool's lighting. It is compatible with the AstralPool® LumiPlus RGB and Zodiac® NL colour LED
spotlights.
Example operation: daily programming and colour selection
• Control the filter pump.
Example operation: daily programming of the filtration system
If more than one light is installed in the pool and the selected color is not synchronized to all lights, reversing
the wiring polarity on the light that is not showing the correct color may be necessary (depending on the
case, inside the Command Connect cabinet or in the junction box near the pool).
Note: Command Connect is not compatible with multiple AstralPool LumiPlus Mini V3 models as color
synchronization does not work.
7. State of the "Smart Relay"
The Smart Relay should only be used by a qualified technician
The Smart Relay is equipped with a button to change operating mode (
as well as a state indicator LED (
LED
Description
Green
Local control mode via Bluetooth (default)
Local control mode via Bluetooth turned OFF
Green
or ON using the iAquaLink+ app. Goes back
flashing
to steady green when the next scheduled
program starts.
Remote control mode (using the iQBridge ZB
Orange
WiFi gateway optional accessory)
Remote control mode turned OFF or ON using
Orange
the iAquaLink+ app. Goes back to steady or-
flashing
ange when the next scheduled program
Red
Error (internal clock delayed after a power
flashing
outage, Wi-Fi connection lost, etc.)
) (see tables below):
starts.
Command Connect - English
.
) (mode indicated by the colour of the LED)
Button
Description
Manual mode OFF on both chan-
First click
nels (always OFF)
Previous active mode ON. Returns
Second click
to the mode that was active
before the first click.
Manual mode ON on both chan-
Third click *
nels (always ON, no scheduling)
Long press (5s) until LED goes to
red, then a short press to go back
Factory reset
to factory default mode (Local
control mode via Bluetooth).
* After the third click, the sequence restarts.