4 - Maintenance
4.1 - Failure assistant chart
Failure mode
The device doesn't
switch on
The rest value is different
than "0"
The display load
measurement is always "0"
The display load
measurement is giving
"EDS"
The display load
measurement is
inconsistent
4.2 - Replacement of the batteries
Remove the 3 screws on each side of the box to get access to the batteries.
Used batteries must be placed in an appropriate recycling container.
(Depending on applicable local rules & regulations).
Causes
The switch is not activated
The batteries are empty
Wrong connection of the batteries
Damaged cables or switch
Hydraulic chamber under pressure at rest
Wrong calibration of the device
Important clearance between socket
and hydraulic piston
Lack of oil
The batteries are empty
Outside of the load measurement range
Wrong calibration of the device
Air presence inside the hydraulic chamber
Wrong calibration of the device
The socket is getting contact with
the washer
Mechanical hard point
Solution
Switch on
Replace the batteries
Check the connection
Contact your BÖLLHOFF saler
Contact your BÖLLHOFF saler
Contact your BÖLLHOFF saler
Select and install spacer(s)
The mandrel of the setting tool has to
be fully screwed
Contact your BÖLLHOFF saler
Replace the batteries
Consult the utilisation limits
Contact your BÖLLHOFF saler
Contact your BÖLLHOFF saler