Descargar Imprimir esta página

General GR4-24LP Manual De Instalación Y Operación página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

• The appliance and its individual shut off valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of ½ PSI
(3.5kPa).
• The appliance must be isolated from the gas supply piping system by closing its individual
manual shut off valve during any pressure testing of the gas supply piping system at test
pressures equal to less than ½ PSI (3.5kPa).
Gas Piping: Gas piping shall be of such size and so installed as to provide a supply of gas sufficient
Regulator information: ¾" NPT (National Pipe Thread) inlet and outlet; factory adjusted for four (4")
inch Water Column (WC) Natural Gas standard and may be converted by qualified personnel to be
used for Propane at ten (10") Water Column pressure.
Prior to connecting the regulator, check the incoming line pressure. The regulator can only withstand
a maximum pressure of ½ PSI (14" WC). If the line pressure is beyond this limit, a step down
regulator before the regulator provided will be required. The arrow forged into the bottom of the
regulator body shows gas flow direction, and should point downstream to the appliance.
CAUTION: Any loose dirt or metal particles, which are allowed to enter the gas lines on this
appliance, will damage the valve and affect its operation. When installing this appliance, all pipe and
fittings must be free from any internal contaminates. It is recommended that a "drip leg" be installed
in-line before the regulator. See diagram above.
Manual Shut Off Valve: A manual shut off valve should be installed upstream from the manifold,
within four (4) feet, (1.2M) of the appliance and in a position where it can be reached in the event of
an emergency.
Checking For Gas Leaks: Using a gas leak detector or a soapy water solution is recommended for
locating gas leaks. Matches, candle flame, or other sources of ignition shall not be used for this
purpose. Check entire piping system for leaks.
DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and water
to meet the full gas input of the appliance. If the
appliance is to be connected to existing piping, it
should be checked to determine if it has adequate
capacity. Joint compound (pipe dope) should be
used sparingly and only on the male threads of the
pipe joints. Such compounds must be resistant to the
action of Liquefied Propane (LP) gases.
WARNING
solution before operating the unit.
6

Publicidad

loading