INSTALLATION
Take out packaging and clean all the cabinet using warm water together with 5% of neutral soap then
dry it with a soft cloth; for the glass parts only use specific products, avoiding the use of water which
can leave on the glasses limestone residues.
Keep a distance from the wall of 10 cm. at least.
Cabinet must be installed on a perfectly even
surface (please settle the adjustable feet), far
away from any heat source (radiators, stoves,
etc) including sun rays.
Good running of the cabinet can be
compromised in cases where the airflow is
disturbed (wind, ventilators, air conditioning
outlets, etc).
Smooth running of the cabinet is assisted when
sufficient air is permitted to flow through the
bottom of the unit; it is very important that the
grills at the base are kept uncovered.
Do not expose the cabinet to rain.
Install and position the unit in such a way so
as to allow easy access to the power socket.
Never use electrical equipment in the
refrigerated compartment
Never place containers of liquid on or
immediately above the ticket counter; should
the content spill out, it would damage the
counter.
THE REFRIGERATOR IS NOT SUITABLE FOR WORKING IN DANGEROUS ENVI-
RONMENT WITH RISK OF FIRE, EXPLOSIONS OR RADIATIONS.
Operation is regular with ambient temperature indicated on technical data plate.
CLIMATE CLASS
0
1
2
3
4
6
5
7
8
ENVIRONMENT OPERATING TEMPERATURE
-10-
20
16
22
25
30
27
40
35
23,9