SECURITY DISTANCES
From NOT combustible object :
•
A > 400 mm
−
From combustible object and from principal wall in rein forced concrete :
•
A > 800 mm
−
The minimal distance between the stove and every flammable object around it is 1.5
•
meter.
1.4 Connection
Before connection check technical data reported in the technical plate ( Chap. 4) and
•
control that it correspond to the ones required in the order.
All heating biomass equipment especially wood stove has to evacuate the combustion
•
products in a flue built in conformity with normative in force.
The following instructions describes „ informations for a good installation „ and it refers
•
to a normative in force but it are not to be consider exhaustive for installations laws.
COLLAR EXHAUST FUMES ASSEMBLY
Take off the collar from the fire door.
•
Place the collar on the top of the stove
•
( see the picture ) assemble it with the
screws.
B > 175 mm
C > 125 mm
B > 350 mm
C > 250 mm
20/76