Door settings
To set door relay strike time
Changing the master code
Changing the master code
For security reasons we recommand changing the master code from default.
G- TECHNICAL FEATURES
> Voltage DC 12V +/-10%
> Badge reading distance 3-6 cm
> Active current < 60mA
> Stand-by current 25±5mA
> Lock load output 3A max
> Operating temperature -45°C ~ 60°C
> Degree of humidity : 10% - 90% RH
> Relay output delay time
> Possible wiring connections : electric lock, gate automation, exit button
> Backlight keys
> 2000 users, supports badge, PIN, badge + PIN
> Full programming from the keypad
> Can be used as a stand alone keypad
> The keyboard can be used to remove the lost badge number, thoroughly eliminate
the hidden safety trouble
> Adjustable Door Output time, Alarm time, Door Open time
> Fast operating speed
> Lock output current short circuit protection
> Indicator light and buzzer
> Frequency : 125kHz
> Maximum transmitted power : 2,82mW
> Protection rating : IP68
RELAY OUTPUT DELAY TIME
* Master code # 4 0~99 # * 0-99 is
to set the door relay time 0-99 seconds
0 New code #
New code #
The master code consists of 6 to 8 digits
en
17