Descargar Imprimir esta página

LEGRAND Celiane 0 676 01 Manual Del Usuario página 5

Publicidad

Céliane
TM
Opening controls
5. CONNECTION
(continued)
Pushbutton wiring (Cat. No. 0 676 03)
6 A - 250 V~
50/60 Hz
0 676 21
D C N
L
L
N
6. OPERATION
Cat. No. 0 676 01: double switch for direct control of opening drives (fixed
position mechanism.
Cat. No. 0 676 02: double
pushbutton for controlling one or more open-
ing drives via automation control units (closing mechanism).
Cat. No. 0 676 03 : double
pushbutton for relay control
nism) of motor opening (without STOP).
roll-up
STOP
roll-down
0 676 01/02
roll-up
roll-down
0 676 03
Technical data sheet: F00562EN/02
M1
0 676 03
L
M
M
L
T
D
C
50 m
(closing mecha-
Updated: 18/07/2012
M2
N
N
M
M
L
T
D
C
N
N
7. TECHNICAL DATA
 7.1 Technical characteristics
Impact tests: IK 04
Penetration by solid/liquids bodies: IP 41 (C15-1000)
 7.2 Material characteristics
Housing: Polycarbonate
 7.3 Electrical characteristics
Self-extinguishing: 650° C / 30 s
Voltage: 250 VAC
Current: 0 676 01 : 6 AX
0 676 02/03 : 6 A
Max. controlled power: 500 W
 7.4 Climatic characteristics
Storage temperatures: - 10° C to + 70° C
Operating temperatures: - 5° C to + 50° C
8. CLEANING
No cleaning.
9. CONFORMITY - APPROVALS
NF
Cat. No(s): 0 676 01/02/03
Mn
M
M
L
T
C
N
N
D
}
no rocker
Created: 27/08/2008
2/2

Publicidad

loading

Este manual también es adecuado para:

Celiane 0 676 02Celiane 0 676 03