ANTI CORROSION SYSTEM
Depending on the model, the water heater is fitted with one of the following anti-corrosion protections:
a) Protek: this is an exclusive modulating electronic system which, in combination with the titanium anode, sets the water
heater power at values within the ideal corrosion protection zone, thereby guaranteeing the maximum service life of the
water heater tank.
The correct operation of the Protek requires that the water heater is permanently connected to a 230 VAC electric power
supply, even when the water heater is not operating.
The correct operation of the Protek is indicated by LED (8) which remains permanently lit.
Battery Kit (optional): models equipped with the Protek system can be converted into water heaters for use with the night
tariff (or time discriminating tariff), by fitting a Battery Kit (installed by a professional technician). The battery guarantees
the power supply to the Protek in the event of a power failure lasting up to 24 hours. In this case the correct operation of
the Protek is indicated by LED (8) which flashes.
In the event of a fault in the Protek system, LED (8) switches off completely and the water heater triggers the correspon-
ding fault code on the display (4).
b) Magnesium anode: this is a protection system for the water heater tank using a sacrificial magnesium anode attached
to the water heater flange.

VACATION MODE

In the event of a temporary absence or journey, the "vacation mode" is activated by pressing the button
(without
disconnecting the water heater from the main power supply or switching off the main power supply of the house).
The water heater enters energy-saving mode by deactivating all unnecessary sources of consumption (resistors, display,
LED...) and maintaining all the safety features activated (de-icing system, electronic anti-corrosion protection,
self-diagnosis...)
De-icing system: The water heater is protected against low temperatures. Whenever the temperature of the accumulated
water is less than 5 °C, the resistors will automatically start operating until a temperature of 10 °C is reached. While the
de-icing system is on the message
is displayed cyclically.
ECO SMART FUNCTION
The ECO function allows the temperature setting to be automatically adjusted according to the weekly habits of the user.
It is activated by pressing the ECO button, or in models without ECO button, the temperature is increased or decreased
(using the + / - buttons) until a value between 65 and 66 °C is shown on the display (4).
When the ECO function is on, the "ECO" LED lights up.