Página 1
All manuals and user guides at all-guides.com MANUALE DI PROGRAMMAZIONE IT PROGRAMMING INSTRUCTIONS UK MANUEL DE RÉGLAGE FR MANUAL DE REGULATIÓN _____________________VP2-HT PH/RX...
Página 2
All manuals and user guides at all-guides.com INDEX ITALIANO ....................................... 6 DESCRIZIONE DELLE CARATTERISTCHE E DEL FUNZIONAMENTO ..................6 DESCRIZIONE PANNELLO FRONTALE ............................. 6 FUNZIONI GENERALI : ..................................6 CONNESSIONI ......................................7 REGOLAZIONI DI FABBRICA ................................7 RIPRISTINO REGOLAZIONI DI FABBRICA ............................7 DISPLAY NEI DIVERSI FUNZIONAMENTI ............................
Página 3
All manuals and user guides at all-guides.com ENGLISH ....................................... 23 DESCRIPTION OF CHARACTERISTICS AND OPERATION ......................23 FRONT PANEL DESCRIPTION ................................23 GENERAL FUNCTIONS: ..................................23 CONNECTIONS ....................................24 DEFAULT SETTINGS ..................................24 DEFAULT SETTINGS RESTORE ................................ 24 DISPLAY IN DIFFERENT DOSING ..............................25 STAND BY (STOP) ....................................
Página 4
All manuals and user guides at all-guides.com FRANCAIS ......................................40 DESCRIPTION DES CARACTERISTIQUES ET DU FONCTIONNEMENT ..................40 DESCRIPTION DU PANNEAU AVANT ............................. 40 FONCTIONS GÉNÉRALES: ................................. 40 CONNECTIONS ....................................41 REGLAGES PAR DEFAUT .................................. 41 RESTAURATION DES PARAMETRES D'USINE ..........................41 AFFICHAGE DANS DIFFÉRENTES TYPES DE DOSAGE .......................
Página 5
All manuals and user guides at all-guides.com ESPANOL ......................................57 DESCRIPCIÓN DE LAS CARACTERÍSTICAS Y FUNCIONAMIENTO..................57 DESCRIPCION DEL PANEL FRONTAL ............................57 FUNCIONES GENERALES: ................................. 57 CONEXIONES ....................................... 58 PARÁMETROS DE FÁBRICA ................................58 RESTAURACIÓN DE AJUSTES DE FÁBRICA ..........................58 DISPLAY EN DIFERENTES OPERACIONES ............................
Página 6
ITALIANO DESCRIZIONE DELLE CARATTERISTCHE E DEL FUNZIONAMENTO Le pompe dosatrici serie “VP2-HT PH/RX” sono ideali per il dosaggio di acido e cloro nelle piscine di piccole, medie e grandi dimensioni. Possono funzionare in modo Manuale, ON-OFF e Proporzionale e la portata è regolabile dal 10% al 100% della portata massima.
Página 7
All manuals and user guides at all-guides.com A - è il cavo di alimentazione elettrica, CONNESSIONI 90-250V-50-60Hz B - è l’ingresso di Enable o consenso al dosaggio(110Vac; 230Vac; a richiesta 24V). OPTIONAL C - è il connettore bnc per la sonda di pH o RX. D - è...
Página 8
All manuals and user guides at all-guides.com DISPLAY NEI DIVERSI FUNZIONAMENTI Misura 7.40pH; Temperatura impostata manualmente a 25°C Funzionamento Manuale, Portata al 30% della portata massima Misura 7.60pH; Temperatura impostata per essere letta dalla sonda di temperatura PT100 ma il sensore non è collegato alla pompa.
Página 9
All manuals and user guides at all-guides.com STRUTTURA DEL MENU PRINCIPALE Premere il tasto ENTER/MENU per 3 secondi per entrare in 3sec programmazione. Con il tasto ▼ spostare il cursore sui sottomenu di interesse. Premere ENTER per entrare nel sottomenu. Se si vuole abbandonare la programmazione e tornare in misura, premere per 3 secondi il tasto ESC.
Página 10
All manuals and user guides at all-guides.com LINGUA All’interno del Menu Set up, selezionare con il cursore “Lingua” e premere ENTER. Scegliere Italiano con i tasti ▼▲ e premere Enter. Se si vuole abbandonare la programmazione e tornare in misura, premere per 3 secondi il tasto ESC. MISURA La scelta della misura è...
Página 11
All manuals and user guides at all-guides.com ENABLE (A RICHIESTA) L’ingresso di enable è un ingresso (230Vac-115Vac) che serve ad abilitare la pompa al dosaggio. Nelle piscine questo ingresso si collega in parallelo all’alimentazione della pompa di ricircolo in modo tale che se la filtrazione è ferma la pompa non possa dosare.
Página 12
All manuals and user guides at all-guides.com MENU UTILITÁ Il menu di Utilità permette di programmare il Ritardo di accensione, l’allarme TAL di sovraddosaggio, permette di scegliere il tipo di sensore di flusso usato (Normalmente Aperto o Normalmente Chiuso), permette di ripristinare i parametri di fabbrica della programmazione e della calibrazione della sonda e permette di definire se la temperatura va misurata con una sonda PT100 in ingresso oppure se va definita manualmente.
Página 13
All manuals and user guides at all-guides.com La pressione del tasto di ESC/SBY fa tornare la pompa nello stato di FUNZIONAMENTO ed azzera il conteggio che riparte immediatamente quando la pompa ricomincia a dosare. All’interno del Menu Utilità, selezionare con il cursore “TAL” e premere ENTER.
Página 14
All manuals and user guides at all-guides.com TEMPERATURA PT100: All’interno del Menu Utilità, selezionare con il cursore “Temperat.” e premere ENTER. Selezionare con i tasti ▼▲ il modo di funzionamento della temperatura: PT100 = scegliere PT100 se è connessa una sonda di temperatura PT100 sull’ingresso E di pag.7.
Página 15
All manuals and user guides at all-guides.com ALLARME All’interno del Menu Relè, selezionare con il cursore “Allarme” e premere ENTER. Selezionare con i tasti ▼▲ il modo di funzionamento del relè desisderato e premere ENTER. N.A= Normalmente Aperto (valore di default) N.C= Normalmente Chiuso Se si vuole abbandonare la programmazione e tornare in misura, premere per 3 secondi il tasto ESC.
Página 16
All manuals and user guides at all-guides.com MENU DOSAGGIO Il menu DOSAGGIO permette di scegliere: il tipo di dosaggio della pompa: MANUALE, PROPORZIONALE, ON-OFF Premere il tasto ENTER/MENU per 3 secondi per entrare in 3sec programmazione. Con il cursore selezionare Dosaggio e premere ENTER. Posizionare il cursore sul tipo di dosaggio da scegliere e premere ENTER per entrare nel sottomenu e procedere alla modifica.
Página 17
All manuals and user guides at all-guides.com PROGRAMMAZIONE E CALIBRAZIONE DELLA POMPA DI PH DOSAGGIO PROPORZIONALE pH Dosaggio proporzionale alla distanza della misura pH dal Setpoint desiderato. La proporzionalità si realizza con la modulazione della portata della pompa da 10-100% della portata massima. Il range di proporzionalità...
Página 18
All manuals and user guides at all-guides.com DOSAGGIO ON-OFF pH Dosaggio costante che si attiva quando la misura si allontana dal valore desiderato. Set Off.= valore della misura che provoca la cessazione del dosaggio Set On = valore della misura che provoca l’inizio del dosaggio. %Portata = %portata di dosaggio costante Rit.On = secondi attesi prima del dosaggio al superamento di Set On.
Página 19
All manuals and user guides at all-guides.com CALIBRAZIONE DELLA SONDA TIPO pH ATTENZIONE, assicurarsi che le soluzioni tampone usate nella calibrazione corrispondano sempre al valore indicato e che non siano inquinate. La compensaziione della temperatura durante la calibrazione del pH è esclusa. TARATURA DELL’OFFSET Immergere la sonda di pH nella soluzione tampone a pH 7.
Página 20
All manuals and user guides at all-guides.com PROGRAMMAZIONE E CALIBRAZIONE DELLA POMPA DI RX DOSAGGIO PROPORZIONALE Rx Dosaggio proporzionale alla distanza della misura RX dal Setpoint desiderato. La proporzionalità si realizza con la modulazione della portata della pompa da 10-100% della portata massima. Il range di proporzionalità...
Página 21
All manuals and user guides at all-guides.com DOSAGGIO ON-OFF Rx Dosaggio costante che si attiva quando la misura si allontana dal valore desiderato. Set Off.= valore della misura che provoca la cessazione del dosaggio Set On = valore della misura che provoca l’inizio del dosaggio. %Portata = %portata di dosaggio costante Rit.On = secondi attesi prima del dosaggio al superamento di Set On.
Página 22
All manuals and user guides at all-guides.com CALIBRAZIONE DELLA SONDA TIPO RX ATTENZIONE, assicurarsi che la soluzione tampone usata nella calibrazione corrisponda sempre al valore indicato e che non sia inquinata. TARATURA DELL’OFFSET Immergere la sonda di Rx nella soluzione tampone.
Página 23
All manuals and user guides at all-guides.com ENGLISH DESCRIPTION OF CHARACTERISTICS AND OPERATION The "VP2-HT PH / RX" dosing pumps series are ideal for dosing acid and chlorine in small, medium and large pools. They can operate in Manual, ON-OFF and Proportional mode and the flowrate is adjustable from 10% to 100% of the maximum flowrate.
Página 24
All manuals and user guides at all-guides.com A - Power cable, 90-250V-50-60Hz CONNECTIONS B - Enable input (dosing consent) (110Vac; 230Vac; upon request 24V). OPTIONAL C - BNC connector for pH probe or Rx probe. D - Level probe connector (3 and 4 contacts). OPTIONAL.
Página 25
All manuals and user guides at all-guides.com DISPLAY IN DIFFERENT DOSING Measure 7.40pH; Temperature set manually at 25 °C. Manual Dosing; Flowrate at 30% of maximum Flowrate. Measure 7.60pH; Temperature set to be read by PT100 probe but the sensor is not connected to the pump.
Página 26
All manuals and user guides at all-guides.com STRUCTURE OF THE MAIN MENU Press the ENTER / MENU button for 3 seconds to enter 3sec programming. Use the ▼ button to move the cursor to the relevant submenus. Press ENTER to enter the submenu. If you want to esc programming and return to measurement, press the ESC button for 3 seconds.
Página 27
All manuals and user guides at all-guides.com LANGUAGE In the Set up menu, select "Language" with the cursor and press ENTER. Choose “English” with the ▼ ▲ keys and press Enter. If you want to esc programming and return to measurement, press the ESC button for 3 seconds.
Página 28
All manuals and user guides at all-guides.com ENABLE (OPTIONAL) The enable input (230Vac-110Vac) gives to the pump the consent to dose. In swimming pool plants this input is connected in parallel with the recirculation pump power supply so that if the filtration is stopped the pump can not dose. In order not to damage the electronic board, do not connect the enable directly in parallel with the recirculation pump power supply, but always use a contactor / relay (see installation manual).
Página 29
All manuals and user guides at all-guides.com MENU UTILITY The Utility menu allows you to program the Delay On, the overdose TAL alarm, allows you to choose the type of flow sensor used (Normally Open or Normally Closed), to restore the factory programming of the parameters and the factory probe calibration and allows to define if the temperature should be measured with a PT100 probe in input or if it must be defined manually.
Página 30
All manuals and user guides at all-guides.com In the Utility menu, select "TAL" by the cursor and press ENTER. Use the ▼ ▲ buttons to select the desired units of dosage and press ENTER. If you want to esc programming and return to measurement, press ESC for 3 seconds.
Página 31
All manuals and user guides at all-guides.com TEMPERATURE PT100: In the Utility Menu, select "Temperat." By the cursor and press ENTER. Use ▼ ▲ buttons to select the temperature operating mode: PT100 = select PT100 if a PT100 temperature probe is connected to input E on page 24.
Página 32
All manuals and user guides at all-guides.com ALARM In the menu Relay, select by the cursor "Alarm" and press ENTER. Select the desired operating mode of the relay with the ▼ ▲ buttons and press ENTER. N.O = Normally Open (default value) N.C = Normally Closed If you want to esc programming and return to measurement, press the ESC key for 3 seconds.
Página 33
All manuals and user guides at all-guides.com MENU DOSING The Dosing menu allows to choose: the type of dosing: MANUAL, PROPORTIONAL, ON-OFF Press the ENTER/MENU button for 3 seconds to enter programming. 3sec By the cursor select “Dosing” and press ENTER. Move the cursor on the desired type of dosage and press ENTER to modify the parameters of dosing.
Página 34
All manuals and user guides at all-guides.com PH PUMP PROGRAMMING AND CALIBRATION pH PROPORTIONAL DOSING This kind of dosing is proportional to the distance of the pH measure from the desired Setpoint. Proportionality is achieved by modulating the pump flow rate from 10-100% of the maximum flow. The proportionality range and the verse are freely programmable (SetP.
Página 35
All manuals and user guides at all-guides.com pH ON-OFF DOSING Constant dosing that activates when the measure moves away from the desired value. Set Off. = Value of the measure that causes the STOP of the dosing Set On = value of the measure that causes the START of the dosing. % Flowrate =% constant dosing flow rate Del.On = seconds expected before dosing when measure exceeds the Set On value.
Página 36
All manuals and user guides at all-guides.com pH PROBE CALIBRATION WARNING, make sure that the buffer solutions used in the calibration correspond to the indicated value and that they are not polluted. Temperature compensation during pH calibration is excluded. OFFSET CALIBRATION Immerse the pH probe in the pH 7 buffer solution.
Página 37
All manuals and user guides at all-guides.com RX PUMP PROGRAMMING AND CALIBRATION RX PROPORTIONAL DOSING This kind of dosing is proportional to the distance of the mV measure from the desired Setpoint. Proportionality is achieved by modulating the pump flow rate from 10-100% of the maximum flow. The proportionality range and the verse are freely programmable (SetP.
Página 38
All manuals and user guides at all-guides.com ON-OFF DOSING Constant dosing that activates when the measure moves away from the desired value. Set Off. = Value of the measure that causes the STOP of the dosing Set On = value of the measure that causes the START of the dosing. % Flowrate =% constant dosing flow rate Del.On = seconds expected before dosing when measure exceeds the Set On value.
Página 39
All manuals and user guides at all-guides.com RX PROBE CALIBRATION WARNING, make sure that the buffer solution used in the calibration correspond to the indicated value and that it is not polluted. OFFSET CALIBRATION Immerse the RX probe in the buffer solution. Wait for the reading stabilization on the display.
Página 40
All manuals and user guides at all-guides.com FRANCAIS DESCRIPTION DES CARACTERISTIQUES ET DU FONCTIONNEMENT Les pompes doseuses de la série "VP2-HT PH / RX" sont idéales pour le dosage d'acide et de chlore dans les petites, moyennes et grandes piscines. Ils peuvent fonctionner en mode Manuel, ON-OFF et Proportionnel et le débit est réglable de 10% à...
Página 41
All manuals and user guides at all-guides.com A - est le câble d'alimentation, CONNECTIONS 90-250V-50-60Hz B - est l'entrée de consentement à dosage (110Vac; 230Vac; 24V sur demande). EN OPTION. C - est le connecteur bnc pour la sonde pH ou D - est le connecteur de la sonde de niveau (contacts 3 et 4).
Página 42
All manuals and user guides at all-guides.com AFFICHAGE DANS DIFFÉRENTES TYPES DE DOSAGE Mesure 7.40pH; Température réglée manuellement à 25 ° C Dosage Manuel, débit à 30% du débit maximal Mesure 7.60pH; Température est réglée pour être lue par la sonde de température PT100 mais n’est pas connecté...
Página 43
All manuals and user guides at all-guides.com STRUCTURE DU MENU PRINCIPAL Appuyez sur le bouton ENTER / MENU pendant 3 secondes 3sec pour entrer en programmation. Avec la touche ▼ déplacer le curseur sur le sous-menu d'intérêt. Appuyez sur ENTER pour entrer dans le sous-menu. Appuyez sur la touche ESC pendant 3 secondes pour quitter la programmation.
Página 44
All manuals and user guides at all-guides.com LANGUE Dans le menu Set up, sélectionnez "Langue" avec le curseur et appuyez sur ENTER. Choisir « Français » avec les touches ▼ ▲ et appuyez sur ENTER. Appuyez sur la touche ESC pendant 3 secondes pour quitter la programmation.
Página 45
All manuals and user guides at all-guides.com ENABLE (OPTIONNEL) L'entrée de Enable est une entrée (230Vac-115Vac) qui sert à activer la pompe au dosage. Dans les piscines, cette entrée est connectée en parallèle avec l'alimentation de la pompe de recirculation, de sorte que si la filtration est arrêtée, la pompe ne peut pas doser.
Página 46
All manuals and user guides at all-guides.com MENU UTILITAIRE Le menu Utilitaire vous permet de programmer l’alarme de surdosage TAL, le délai d’allumage, vous permet de choisir le type de capteur de débit utilisé (normalement ouvert ou normalement fermé), rétablir les paramètres d'usine de la programmation et d'étalonnage de la sonde.et de définir si la température doit être mesurée avec une sonde PT100 ou si elle doit être définie manuellement.
Página 47
All manuals and user guides at all-guides.com Dans le menu Utilitaire, sélectionnez "TAL" avec le curseur et appuyez sur ENTER. Utilisez les touches ▼ ▲ pour entrer les unités de dosage souhaitées, puis appuyez sur ENTER. Appuyez sur la touche ESC pendant 3 secondes pour quitter la programmation RESTAURER LES PARAMÈTRES DE PROGRAMMATION ET D'ÉTALONNAGE D'USINE Avertissement: la restauration de la programmation n'a aucune influence sur la langue et le mot de passe (password).
Página 48
All manuals and user guides at all-guides.com TEMPERATURE PT100: Dans le menu Utilitaires, sélectionnez "Temperat." avec le curseur et appuyez sur ENTER. Utilisez les touches ▼ ▲ pour sélectionner le mode de fonctionnement de la température: PT100 = choisissez PT100 si une sonde de température PT100 est connectée à...
Página 49
All manuals and user guides at all-guides.com ALARME Dans le menu Relais, sélectionnez "Alarme" avec le curseur et appuyez sur ENTER. Sélectionnez le mode de fonctionnement du relais souhaité avec les touches ▼ ▲ et appuyez sur ENTER. N.O = normalement ouvert (valeur par défaut) N.F = normalement fermé.
Página 50
All manuals and user guides at all-guides.com MENU DOSAGE Le menu DOSAGE vous permet de choisir: le type de dosage de la pompe: MANUEL, PROPORTIONNEL, ON-OFF Appuyez sur le bouton ENTER / MENU pendant 3 secondes 3sec pour entrer en programmation. Avec le curseur, sélectionnez Dosage et appuyez sur ENTER.
Página 51
All manuals and user guides at all-guides.com PROGRAMMATION ET ÉTALONNAGE DE LA POMPE DE PH DOSAGE PROPORTIONNEL DE pH Dosage proportionnel à la distance entre la mesure du pH et le point de consigne souhaité. La proportionnalité est obtenue en modulant le débit de la pompe de 10 à 100% du débit maximal. La plage de proportionnalité...
Página 52
All manuals and user guides at all-guides.com DOSAGE ON-OFF DE pH Dosage constant qui s'active lorsque la mesure s'éloigne de la valeur souhaitée. Set Off = valeur de la mesure qui provoque l'arrêt du dosage Set On = valeur de la mesure qui provoque le début du dosage. % Débit =% débit constant de dosage Ret.On = secondes attendues avant le dosage lorsque la mesure dépasse le Set On.
Página 53
All manuals and user guides at all-guides.com ETALONNAGE DE LA SONDE DE PH ATTENTION, assurez-vous que les solutions tampons utilisées lors de l'étalonnage correspondent toujours à la valeur indiquée et qu'elles ne sont pas polluées. La compensation de température pendant l'étalonnage du pH est exclu. ETALONNAGE DE L’OFFSET Immerger la sonde de pH dans une solution tampon à...
Página 54
All manuals and user guides at all-guides.com PROGRAMMATION ET ÉTALONNAGE DE LA POMPE DE REDOX DOSAGE PROPORTIONNEL DU RX Dosage proportionnel à la distance entre la mesure du Rx et le point de consigne souhaité. La proportionnalité est obtenue en modulant le débit de la pompe de 10 à 100% du débit maximal. La plage de proportionnalité...
Página 55
All manuals and user guides at all-guides.com DOSAGE ON-OFF Dosage constant qui s'active lorsque la mesure s'éloigne de la valeur souhaitée. Set Off = valeur de la mesure qui provoque l'arrêt du dosage Set On = valeur de la mesure qui provoque le début du dosage. % Débit =% débit constant de dosage Ret.On = secondes attendues avant le dosage lorsque la mesure dépasse le Set On.
Página 56
All manuals and user guides at all-guides.com ETALONNAGE DE LA SONDE DE REDOX ATTENTION, assurez-vous que les solutions tampons utilisées lors de l'étalonnage correspondent toujours à la valeur indiquée et qu'elles ne sont pas polluées. ETALONNAGE DE L’OFFSET Immerger la sonde de Rx dans une solution tampon.
Página 57
All manuals and user guides at all-guides.com ESPANOL DESCRIPCIÓN DE LAS CARACTERÍSTICAS Y FUNCIONAMIENTO. Las bombas dosificadoras "VP2-HT PH / RX" son ideales para dosificar ácido y cloro en piscinas pequeñas, medianas y grandes. Pueden operar en modo Manual, ON-OFF y Proporcional, y el caudal es ajustable del 10% al 100% del flujo máximo. Estas bombas regulan el caudal variando la velocidad de rotación del soporte del rollo.
Página 58
All manuals and user guides at all-guides.com A- es el cable de alimentación, CONEXIONES 90-250V-50-60 Hz B - es la entrada de B de habilitación o consentimiento a dosificación (110Vac; 230Vac; 24V a pedido). OPCIONAL C - es el conector bnc para la sonda de pH o RX. D - es el conector de la sonda de nivel (contactos 3 y 4).
Página 59
All manuals and user guides at all-guides.com DISPLAY EN DIFERENTES OPERACIONES Medida 7.40pH; Temperatura ajustada manualmente a 25 ° C Dosification Manual, Caudal a 30% del caudal máximo Medida 7.60pH; Temperatura ajustada para ser leída por la sonda de temperatura PT100 pero el sensor no está...
Página 60
All manuals and user guides at all-guides.com ESTRUCTURA DEL MENÚ PRINCIPAL Pulse el botón ENTER / MENU durante 3 segundos para 3sec entrar en la programación. Con la tecla ▼ mover el cursor en el submenú de interés. Pulse ENTER para entrar en el submenú. Si desea abandonar la programación y volver a la medición, presione la tecla ESC durante 3 segundos.
Página 61
All manuals and user guides at all-guides.com IDIOMA En el menú Set up, seleccione "Idioma" con el cursor y presione ENTER. Elija “Espanol” con las teclas ▼ ▲ y presione ENTER. Si desea abandonar la programación y volver a la medición, presione la tecla ESC durante 3 segundos.
Página 62
All manuals and user guides at all-guides.com ENABLE (OPCIONAL) La entrada de habilitación (ENABLE) es una entrada (230Vac-115Vac) que sirve para habilitar la bomba a la dosis. En las piscinas, esta entrada se conecta en paralelo con la fuente de alimentación de la bomba de recirculación, de modo que si se detiene la filtración, la bomba no puede dosificar.
Página 63
All manuals and user guides at all-guides.com MENÚ UTILIDADES El menú Utilidades le permite programar el Retraso de ignición, la alarma de sobredosis TAL, le permite elegir el tipo de sensor de flujo utilizado (Normalmente Abierto o Normalmente Cerrado), restaurar los parámetros de fábrica de la programación y calibración de la sonda y le permite definir si la temperatura debe medirse con una sonda PT100 en de entrada o si se debe definir manualmente.
Página 64
All manuals and user guides at all-guides.com La presione de la tecla ESC/SBY vuelve al estado de FUNCIONAMIENTO y el conteo reinicia cuando la bomba empieza la dosificación. En el menú Utilidades, seleccione "TAL" con el cursor y presione ENTER. Use las teclas ▼...
Página 65
All manuals and user guides at all-guides.com TEMPERATURA PT100: En el menú Utilidades, seleccione " Temperat.” " con el cursor y presione ENTER Use las teclas ▼ ▲ para seleccionar el modo de operación de la Temperatua deseado: PT100 = elija PT100 si una sonda de temperatura PT100 está...
Página 66
All manuals and user guides at all-guides.com ALARMA En el menú Relé, seleccione "Alarma" con el cursor y presione ENTER. Use las teclas ▼ ▲ para seleccionar el modo de operación del relè deseado y presione ENTER. N.A = Normalmente Abierto (valor predeterminado) N.C = Normalmente Cerrado Si desea abandonar la programación y volver a la medición, presione la tecla ESC durante 3 segundos.
Página 67
All manuals and user guides at all-guides.com MENÚ DE DOSIFICACIÓN El menú de DOSIFICACIÓN le permite elegir: El tipo de dosaje de la bomba: MANUAL, PROPORCIONAL, ON-OFF. Pulse la tecla ENTER/MENU durante 3 segundos para entrar 3sec en la programación Con el cursor selecciona Dosificación y pulsa ENTER.
Página 68
All manuals and user guides at all-guides.com PROGRAMACIÓN Y CALIBRACIÓN DE BOMBA DE PH DOSIFICACIÓN PROPORCIONAL pH Dosificación proporcional a la distancia de la medición del pH desde el punto de ajuste deseado (Setpoint). La proporcionalidad se realiza modulando el caudal de la bomba de 10 a 100% del caudal máximo. El rango de proporcionalidad y el verso son libremente programables (SetP.
Página 69
All manuals and user guides at all-guides.com DOSIFICACIÓN ON-OFF PH Dosificación constante que se activa cuando la medición se aleja del valor deseado. Set Off. = Valor de la medida que provoca el cese de la dosificación. Set.On = Valor de la medida que causa el inicio de la dosificación. % Caudal =% del Caudal de dosificación constante Ret.On = segundos esperados antes de la dosificación cuando se excede Set On.
Página 70
All manuals and user guides at all-guides.com CALIBRACIÓN DE LA SONDA DE PH ADVERTENCIA, asegúrese de que las soluciones tampón utilizadas en la calibración siempre correspondan al valor indicado y que no estén contaminadas. La compensación de temperatura durante la calibración de pH es excluida. CALIBRACION OFFSET Sumerja la sonda de pH en la solución tampón de pH 7.
Página 71
All manuals and user guides at all-guides.com PROGRAMACIÓN Y CALIBRACIÓN DE BOMBA DE RX DOSIFICACIÓN PROPORCIONAL RX Dosificación proporcional a la distancia de la medición del RX desde el punto de ajuste deseado (Setpoint). La proporcionalidad se realiza modulando el caudal de la bomba de 10 a 100% del caudal máximo. El rango de proporcionalidad y el verso son libremente programables (SetP.
Página 72
All manuals and user guides at all-guides.com DOSIFICACIÓN ON-OFF RX Dosificación constante que se activa cuando la medición se aleja del valor deseado. Set Off. = Valor de la medida que provoca el cese de la dosificación. Set.On = Valor de la medida que causa el inicio de la dosificación. % Caudal =% del Caudal de dosificación constante Ret.On = segundos esperados antes de la dosificación cuando se excede Set On.
Página 73
All manuals and user guides at all-guides.com CALIBRACIÓN DE LA SONDA DE RX ADVERTENCIA, asegúrese de que las soluciones tampón utilizadas en la calibración siempre correspondan al valor indicado y que no estén contaminadas. CALIBRACION OFFSET Sumerja la sonda de RX en la solución tampón.
Página 74
All manuals and user guides at all-guides.com Rev 1.1 Cod. 00.009.126...
Página 75
All manuals and user guides at all-guides.com Rev 1.1 Cod. 00.009.126...
Página 76