2.
Remove the front cover using an appropriate screwdriver.
3.
Mount the thermostat on a flat surface. Drill two 6 mm holes and
insert a nylon anchor plug in each hole. Drill two 2.6 mm holes
when mounting the thermostat on a wooden surface.
4.
Wire the thermostat. The thermostat is designed for maximum
230 V~, 7 A. Never exceed these limits!
From left to right, the connection terminals are: neutral
input (N in), live input (L in) and live output (L out). Use wires
with diameter of 1.0-2.5 mm² and connect accordingly.
5.
Replace the front cover and switch on the mains power supply.
The working LED [2] will turn blue to indicate proper connection.
6.
Operation
6.1
Setting the Temperature
1.
Slide the on-off switch [1] to the HEAT position. The thermostat
will switch on and enter the temperature control status.
2.
Turn the temperature SET knob [4] to the desired room
temperature. The working LED [2] will light.
3.
Slide the on-off switch to the OFF position to switch off the
thermostat.
Note
Due to the built-in delay, the thermostat will not respond
immediately when the temperature setting is changed.
6.2
Setting the Eco Mode
The eco mode is an energy-saving mode, which temperature is 5 °C
lower than the set temperature.
How to set the eco mode: