Descargar Imprimir esta página

Adler europe AD 8081 Manual De Uso página 6

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
Possible Cause 2: Insufficient power.
Solution for possible cause 2: Move the unit to another outlet. Check your circuit breaker. (Refer to the rating label on the back of the
unit to determine the Amperage draw).
Possible Cause 4: DC power cord
Solution for possible cause 4: Test the unit with another power supply, e.g. another vehicle with a known working DC power outlet.
Possible Cause 5: Disconnected wires.
Solution for possible cause 5: Contact customer service.
Problem II: Unit is making strange noises.
Possible Cause 1: The unit is not level.
Solution 1: Move the unit to a flat level surface.
Problem III: Unit is making a loud continuous metallic knocking or pinging sound.
Possible Cause 1: Unit may have been shipped on its side.
Solution 1: Shut off the unit. Let the unit sit on a level surface for at least 24 hours and restart.
Possible Cause 2: Damaged compressor
Solution 2: Contact customer service.
Solution: Contact an electrician if the unit works in a different room or circuit.
Problem V: The control panel lights blink randomly.
Possible Cause: Unit may have a faulty control panel.
Solution: Restart the unit, and if issue persists, contact customer service.
Problem VI: Unit has an HH error
Possible Cause: Ambient temperature has exceeded 40℃.
Solution: Restart the unit, and if issue persists, contact customer service.
Problem VII: Unit has an OC error.
Possible Cause: Thermostat error was detected.
Solution: Restart the unit, and if issue persists, contact customer service.
Problem VIII: Unit has a S.C. error
Possible Cause: A short circuit in thermostat detected.
Solution: Restart the unit, and if issue persists, contact customer service.
Problem IX: Unit has power, but the compressor does not run.
Possible Cause 1: Ambient temperature is too low.
Solution 1: Move the unit to a warmer location.
Possible Cause 2: Disconnected wire.
Solution 2: Contact customer service.
TECHNICAL DATA
Capacity: 40 liters
Power supply:
• DC 12V / 24V - car lighter socket
• 230V ~50/60Hz - mains socket after using an external power supply (not included)
Refrigerant: R600a / 40 g
Climate class: S / SN
Isolation: C5H10
Rated Power Consumption: 45W
Maximum Rated Current: 3,7A
To protect your environment: please separate carton boxes and plastic bags and dispose them in corresponding waste
bins. Used appliance should be delivered to the dedicated collecting points due to hazarsous components, which may
effect the environment. Do not dispose this appliance in the common waste bin.
BITTE LESEN SIE SORGFÄLTIG DURCH UND BEWAHREN SIE DIE ZUKÜNFTIGE
1. Lesen Sie vor der Verwendung des Geräts die Bedienungsanleitung und befolgen Sie
die darin enthaltenen Anweisungen. Der Hersteller haftet nicht für Schäden, die durch die
Verwendung des Geräts entstehen, die gegen den Verwendungszweck oder den
unsachgemäßen Betrieb verstoßen.
2. Das Gerät ist nur für den Heimgebrauch bestimmt (nicht gewerblich / privat). Nicht für
andere Zwecke verwenden, die nicht dem Verwendungszweck entsprechen. Das Gerät ist
für Campingzwecke geeignet und kann an mehr als eine Stromquelle angeschlossen
werden.
3. Das Gerät sollte je nach Bedarf an die Steckdose "Zigarettenanzünder" im Auto mit
DEUTSCH
ALLGEMEINE SICHERHEITSBEDINGUNGEN
WICHTIGE SICHERHEITSANWEISUNGEN
REFERENZ AUF
Device is made in class I of insulation and has to be connected
only to power outlet with ground circuit.
Device is compliant with EU directives:
Low voltage directive (LVD)
Electromagnetic compatibility (EMC)
Device marked CE mark on rating label