SHORT-TERM SETTING OF A REMOTE CONTROL
This function makes it possible to store a remote control temporarily, for example, with
the purpose of setting the limit switches during assembly in the factory. A later final
saving of the remote control will be possible using the appropriate command sequence
(see: "SETTING THE FIRST REMOTE CONTROL"). The operations described below can
be carried out only when the control unit has just come out of the factory or after a
full memory clearing (see: "FULL MEMORY CLEARING"). The control unit makes the
following operations possible only within the time limits described in order to make sure
that the short-term setting is used only in the installation or factory setting phase and
not during daily use. Power up the control unit, make sure that no other control units
having an empty memory are powered up in the same operating range.
Within 30 seconds after start, press the B and C buttons simultaneously until the
motor gives a confirmation signal.
The remote control will remain stored for 5 minutes, while the control unit is
powered up. After 5 minutes or when the control unit has its power cut off, the remote
control will be cancelled.
T1: First remote control to be set
EU DECLARATION OF CONFORMITY
CHERUBINI S.p.A. declares that the product is in conformity with the relevant Union
harmonisation legislation:
Directive 2014/53/EU, Directive 2011/65/EU.
The full text of the EU declaration of conformity is available upon request at the
following website: www.cherubini.it.
SPECIAL FUNCTIONS
+
B
C
+
B
C
T1
36