Using the Breathe Easy™
8
Using the Breathe Easy™
WARNING!
!
Eye damage may result from directly viewing the light produced by
these lamps. To reduce the risk of exposure to UV radiation, take
UV-radiation protective measures for personnel during servicing.
➤ Connect one end of the 12 V power cable to the socket (fig. 2 2, page 2).
➤ Plug the other end of the cable into the 12 V source.
➤ Move the switch (fig. 2 1, page 2) to the required position:
– II (maximum purification, recommended): The fan operates at maxi-
mum speed. The ultraviolet lamp is on (you can see a blue glow
through the vents).
– I: The fan operates at lower speed. The ultraviolet lamp is on (you can
see a blue glow through the vents).
– 0: The fan and the ultraviolet lamp are switched off.
9
Replacing the ultraviolet lamp and the
nano-mesh divider
CAUTION! Ultraviolet lamp may cause injury
!
Ultraviolet lamps are made of glass and are fragile. Safety eyewear
and puncture resistant gloves must be worn when handling an ul-
traviolet lamp
Ultraviolet lamps have a limited service life. After around 9000 service hours
(about a year of continuous use) they lose their germicidal effectiveness. You
must therefore replace the lamp after this period, even if it still lights up.
NOTE
I
Each time you switch the ultraviolet lamp on and off, you reduce its
service life by about an hour.
24
Breathe Easy™
EN