To refill the pulse unit
Keep the pulse unit at normal room temperature.
A
Before the refill: Let the bubbles in the oil fade away, at least 30 min. after last run.
Check that there are no bubbles in the oil and that the pulse unit is completely full (100%)
before reducing the oil volume according to operation No. 11.
Correct oil quantity: Fill to 100%, then reduce according to table.After
the refill - check the tightening torque, and pulse frequency according
to Test methods.
Oil volume to be re-
Approx. oil volume
duced from 100%
in pulse-unit
0,2 ± 0,05 ml
5.5 ml
7
Pos. 7.
Important: Wait minimum
30 minutes after last usage
(temp ca. 20° C).
No.: 459 663
8
9
Oil level
11
10
1 ml
"100 % filled"
Reduce
according to table
2 Nm
2.5 mm
12