1 INFORMATION ON THIS DOCUMENT
1.1 Function
These operating instructions provide information on installation, connection and safe
use for the following articles: CS AR-46••••.
1.2 Target audience
The operations described in these operating instructions must be carried out by qua-
lified personnel only, who are fully capable of understanding them, and with the tech-
nical qualifications required for operating the machines and plants in which the safety
devices are to be installed.
1.3 Application field
These instructions apply exclusively to the products listed in the Function Section,
and their accessories.
1.4 Original instructions
The Italian language version is the original set of instructions for the device. Versions
provided in other languages are translations of the original instructions.
2 SYMBOLS USED
This symbol indicates any relevant additional information
Attention: Any failure to observe this warning note can cause damage or mal-
function, including possible loss of the safety function.
3 DESCRIPTION
3.1 Device description
The safety device described in this manual is defined according to the Machinery
Directive 2006/42/EC as logic component for safety functions.
The safety modules to which these usage instructions refer are devices specifically
designed and manufactured for use on industrial machines. Upon opening of at least
one channel, the safety function ensures that the safety relays must open their ou-
tput contacts within the defined reaction time. The safety outputs of the module are
enabled only if the channels CH1 and CH2 are consistently closed and after activating
the START signal.
3.2 Device functions
This device is suitable for the following applications: as a module for emergency
stop, for end position monitoring with movable guards, for magnetic safety sensors in
safety circuits up to category 1 acc. to EN ISO 13849-1, up to SIL 1 acc. to EN 62061
and up to PL c acc. to EN ISO 13849-1.
- Input with 1 or 2 channels.
- The SIL 3 / PL e safety function is only available with the two redundant inputs
configuration.
- Output contacts: 1 NO contact.
- Automatic start.
With reference to the "automatic" operating mode, consider RES 1.2.3 of the
Machinery Directive 2006/42/EC: "For machinery functioning in automatic mode, the
starting of the machinery, restarting after a stoppage, or a change in operating condi-
tions may be possible without intervention, provided this does not lead to a hazardous
situation".
- Connection of input channels of opposite potentials.
- Can be connected to semiconductor outputs and to magnetic safety sensors.
- Short circuit detection function of the control elements by means of safety system
with self-monitoring and redundancy.
- LED indicators for switching state of the channels 1, 2 and for the power supply
voltage.
- In the event of a failure, the device switches to a safe state and deactivates the
safety output.
- Screw terminals or plug-in terminals with screw connections or spring terminals
(depending on the model).
- Snap-mounting on DIN rails.
3.3 Intended use of the device
- The device described in these operating instructions is designed to be applied on
industrial machines.
- The direct sale of this device to the public is prohibited. Installation and use must be
carried out by qualified personnel only.
- The use of the device for purposes other than those specified in these operating
instructions is prohibited.
- Any use other than as expressly specified in these operating instructions shall be
considered unintended by the manufacturer.
- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications
to it;
b) using the product in a field of application other than as described in the TECHNICAL
DATA Section.
Pizzato Elettrica Srl
e-mail:
via Torino, 1
web site:
36063 MAROSTICA (VI)
www.pizzato.com
ITALY
Phone:
4 OPERATION
4.1 Operating diagram
Automatic
start:
t
A
Legend:
t
: Simultaneity time
C
t
: Response time
A
Notes: The configurations with one channel are obtained taking into consideration the
S11/S12 input only. In this case it is necessary to consider time t
S11/S12, time t
referred to the supply and time t
R
4.2 Wiring diagrams
Emergency stop circuits
Input configuration with automatic start
2 channels and 1 emergency stop button
A1
S21
2 channels and 2 emergency stop buttons
A1
S21
2 channels and 4 switches
A1
S21
Monitoring of movable guards and magnetic safety
sensors
The safety module can monitor emergency stop circuits,
control circuits for movable guards as well as magnetic
safety sensors. Replace the emergency stop contacts with
switch contacts or sensor contacts.
4/18
info@pizzato.com
+39.0424.470.930
t
t
t
t
t
R1
C
A
A
R
t
: Release time
R1
t
: Release time in absence of power
R
supply
referred to input S11/S12.
A
S11
S31
S12
CS AR-46
S41
S22
S42
A2
S11
S31
S12
CS AR-46
S22
S41
S42
A2
S11
S31
S12
CS AR-46
S22
S41
S42
A2
Magnetic sensors can be connected only in dual
channel configuration.
ZE FOG48A23-EU
A1/A2
S11/S12
S21/S22
S31/S32
S41/S42
13/14
referred to input
R1