Descargar Imprimir esta página

Publicidad

Enlaces rápidos

Manual
Submersible
Pump
CAUTION
Read this manual thoroughly
before using the tool.
For DIRTY
Water
Applies for:
Code
Model
27199
BOS-1-1/2SPP

Publicidad

loading

Resumen de contenidos para PRETUL BOS-1-1/2SPP

  • Página 1 Manual Submersible For DIRTY Water Pump Applies for: Code Model 27199 BOS-1-1/2SPP Read this manual thoroughly CAUTION before using the tool.
  • Página 2 Manual before Parts using the tool. Installation Keep this manual for future references. Start Up The illustrations in this manual are for reference Maintenance only. They might be different from the real tool. Troubleshooting Notes Authorized Service Centers Warranty BOS-1-1/2SPP ENGLISH...
  • Página 3 Technical Data BOS-1-1/2SPP Code 27199 Description Submersible Pump for Dirty Water Voltage and Frequency 127 V 60 Hz Power 1 1/2 Hp Current Speed 3450 RPM Flow Rate 240 L/min Maximum Depth 22.9’ Maximum Height / Maximum 27.8’ Value of Total Gauged Height Power Cable 32.8’...
  • Página 4 General power tool safety warnings WARNING! Read carefully all safety warnings and instruction listed below. Failure to comply with any of these warnings may result in electric shock, fire and / or severe damage. Save all warnings and instructions for future references.
  • Página 5 Safety Warnings for Submersible Pumps WARNING • Do not use the pump in the nearness Appropriate Use of the Pump of areas where explosives, flammable liquids or gases are • This line of submersible pumps is designed to pump kept. fresh and clear water from springs, wells and other water CAUTION •...
  • Página 6 Safety Warnings for Submersible Pumps • The connection source shall come from • In the event the power cable is CAUTION WARNING properly installed and tested grounded outlets. Power damaged, disconnect the pump from the power supply from the power supply and fuse shall match the pump’s immediately! Never run a pump if the power cable is technical data.
  • Página 7 Installation • Before installing double check the CAUTION pump, cable and plug are not showing any damage due to transportation and storage. • Connect the hose to the hose into the connection most suitable for the needs (A). Use a clamp to fasten the soft hoses and a soldered flange for steel hoses.
  • Página 8 Start Up WARNING • Avoid the pump operating dry, Float Switch otherwise it can break down. When the water stops • The float switch goes On and OFF automatically flowing, disconnect the pump immediately. depending on the water level height. When the float •...
  • Página 9 Troubleshooting Problem Cause Solution The pump cannot be • No power. • Check the cable, plug and fuse. turned on or it • The float is not changing its • Set the pump correctly into the pool, well, etc. suddenly stops while position.
  • Página 10 Notes ENGLISH...
  • Página 11 Authorized Service Centers In the event of any problem contacting a Authorized Service Center, please see our webpage www.truper.com to get an updated list, or call our toll-free numbers 800 690-6990 or 800 018-7873 to get information about the nearest Service Center. DE TODO PARA LA CONSTRUCCIÓN FIX FERRETERÍAS AGUASCALIENTES...
  • Página 12 Model Brand 27199 BOS-1-1/2SPP Warranty. Duration: 1 year. Coverage: parts, components and workmanship against manufacturing or operating defects, except if used under conditions other than normal; when it was not operated in accordance with the instructive; was altered or repaired by personnel not authorized by Truper .

Este manual también es adecuado para:

27199