Hydro
Pneumatic
Pressure
Boosting System
CAUTION
Read the user's manual thoroughly
before operating this tool.
Tank Capacity
6.3 gal
13.2 gal
20183
Applies for:
Codes
Models
20183
HIDR-1/2x24P
20184
HIDR-1/2x50P
20184

Publicidad

Tabla de contenido
loading

Resumen de contenidos para PRETUL HIDR-1/2x24P

  • Página 1 Manual Hydro Tank Capacity 6.3 gal 13.2 gal Pneumatic 20183 20184 Pressure Applies for: Codes Models Boosting System 20183 HIDR-1/2x24P 20184 HIDR-1/2x50P Read the user’s manual thoroughly CAUTION before operating this tool.
  • Página 2: Tabla De Contenido

    Installation Keep this manual for future references. Pressure Switch The illustrations in this manual are for reference Start Up only. They might be different from the real tool. Maintenance Troubleshooting Notes Authorized Service Centers Warranty Policy HIDR-1/2x24P HIDR-1/2x50P ENGLISH...
  • Página 3: Technical Specifications

    Technical Specifications HIDR-1/2x24P HIDR-1/2x50P Code 20183 20184 Description Hydro Pneumatic Pressure Boosting System Voltage 127 V Frequency 60 Hz Current 3.5 A Speed 3450 RPM Inlet and Outlet Diameter 1” x 1” Maximum Suction Depth 26.2 ft Maximum Height (Maximum value of 65.6 ft...
  • Página 4: General Power Tools Safety Warnings

    General Power Tools Safety Warnings WARNING! Read carefully all safety warnings and instructions listed below. Failure to comply with any of these warnings may result in electric shock, fire and / or severe damage. Save all warnings and instructions for future references.
  • Página 5: Safety Warnings For Water Pumps

    Safety Warnings for Water Pumps CAUTION • Do not install the device outdoors or Adequate Uses wet areas. WARNING • Do not install the device in areas • The equipment is a stationary device designed to pump where there is danger of explosion or near combustible neutral, clean liquids with no abrasive solids suspended, liquids or gases.
  • Página 6: Parts

    Parts Pump-tank inter-connection hose Water Closed electric motor Outlet Manometer with external ventilation Peripheral pump Power Cable Pressure Switch (pressurestat) Water Input Support to fix the Tank equipment Purging ENGLISH...
  • Página 7: Installation

    Installation Set Up • The equipment shall be installed in a dry place, safeguarding from outdoors and allowing air flow for its correct ventilation (A). Environment temperature shall not exceed 104 °F. • Use bolts to fix the equipment to a concrete base to prevent any vibration (B). The hydro pneumatic equipment shall be installed in horizontal position to assure good performance.
  • Página 8: Electric Connection

    Installation Electric connection • Ask a professional electrician to make the power connection to the power supply. Comply with the corresponding mandatory rules. • The fixed installation shall incorporate a device to assure the omni-polar disconnection of the energy feed. •...
  • Página 9: Maintenance

    Maintenance • The hydro-pneumatic equipment does not require maintenance only if the following caution measures are followed: • When there is risk of freezing, empty the pump completely removing the suction pipe (B). Remember to purge the pump before starting it again. •...
  • Página 10: Notes

    Notes ENGLISH...